Published by Iva PAVLOVA-MARCINIAK, Czestochowa University of Technology, Institute of Power Engineering Abstract. The paper presents the analysis of modern nuclear energy development possibilities in Poland, which is considered as an ecological energy source. As the demand for electrical energy is constantly growing the use of such energy sources in one of the ways toContinue reading “Nuclear Power Plants Application in Poland – A Way to Meet the Requirements of the Paris Agreement”
Tag Archives: Power Distribution
A Review of Electricity and Renewable Energy Sectors Status and Prospect in Jordan
Published by Mohammad Abu Sarhan, Andrzej Bien´, Szymon Barczentewicz, Rana Hassan, AGH University of Science and Technology Abstract. In Jordan, there are many extensive challenges that the country faces against the national economy growth. This is mainly because Jordan has limited primary energy resources and imports more than 90% of natural gas and crude oilContinue reading “A Review of Electricity and Renewable Energy Sectors Status and Prospect in Jordan”
An Introduction To Flow Batteries
Published by Kevin Clemens, EE Power – Technical Articles: An Introduction To Flow Batteries, February 06, 2023. Lithium-ion batteries get all the headlines, but flow batteries are a viable option, particularly for large-scale grid storage. Lithium-ion batteries have become the energy storage device of choice for cell phones, laptop computers, personal handheld devices, and electric vehiclesContinue reading “An Introduction To Flow Batteries”
Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems
Published by Paweł PIJARSKI, Sylwester ADAMEK, Robert JĘDRYCHOWSKI, Klara SEREJA, Lublin University of Technology, Department of Electrical Networks and Security Abstract. An increasing number of connected prosumer installations, mainly photovoltaic ones, can cause problems with the operation of lowvoltage networks such as voltage fluctuations. These problems can be solved by an adequate control of theContinue reading “Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems”
Distance Protection Analysis Applied for Distribution System with Distributed Generation
Published by João T. L. S. CAMPOS1,2, Huilman S. SANCA1, Flavio B. COSTA3, Benemar A. de SOUZA1, Universidade Federal de Campina Grande (1), Universidade Potiguar (2), Universidade Federal do Rio Grande do Norte (3) Abstract. In power systems, the over-current protection scheme and, optionally with directional function, and distance function are the main protection used,Continue reading “Distance Protection Analysis Applied for Distribution System with Distributed Generation”
Capabilities of Polish Power Plants – Advantages and Threats
Published by Paweł SZMITKOWSKI1, Sylwia ZAKRZEWSKA1, Agnieszka GIL2, Paweł ŚWIDERSKI1Siedlce University, Social Science and Security Institute (1), Siedlce University, Institute of Mathematics and Physics (2) Abstract. The Polish energy infrastructure is very diverse, both in terms of the distribution of power plants in particular regions of the country, as well as the fuels used inContinue reading “Capabilities of Polish Power Plants – Advantages and Threats”
Application of Additional Grounded Wires in High Voltage Overhead Power Lines to Reduce the Intensity of Electric Field Generated by Phase Wires
Pubsliehd by Jacek GUMIELA1, Dariusz SZTAFROWSKI1 Politechnika Wrocławska, Katedra Energoelektryki (1) Abstract. To minimize interference with the environment it is important to make every effort already at the design stage to spare the trouble associated with additional investment later on. Due to the value of land in urban areas, it is beneficial to take necessaryContinue reading “Application of Additional Grounded Wires in High Voltage Overhead Power Lines to Reduce the Intensity of Electric Field Generated by Phase Wires”
The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid
Published by Michał KONARSKI, Paweł WĘGIEREK, Lublin University of Technology, Faculty of Electrical Engineering and Computer Science, Lublin, Poland Abstract. The article presents assumptions, characteristics and conclusions of functional tests of a pilot implementation of a power restoration system in one of the Distribution System Operators. The main objective of conducted and described tests wasContinue reading “The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid”
Selected Aspects of Photovoltaic Power Station Operation in the Power System
Published by Andrzej LANGE1, Marian PASKO2University of Warmia and Mazury, Department of Electrical and Power Engineering, Electronics and Automation (1), Silesian University of Technology, Institute of Electrical Engineering and Computer Science (2) Abstract. This paper presents the results of a five-year study of a 1 MW photovoltaic power station in the Warmia and Mazury Province.Continue reading “Selected Aspects of Photovoltaic Power Station Operation in the Power System”
A 3 kV DC Electric Traction System Modernisation for Increased Speed and Trains Power Demand – Problems of Analysis and Synthesis
Published by Adam SZELĄG, Tadeusz MACIOŁEK, Politechnika Warszawska, Instytut Maszyn Elektrycznych Abstract. A 3 kV DC supply system, used on railways in Poland, since 1936, has power delivery capacity that allows reaching by trains a maximum speed of 250 km/h. Currently, the maximum trains service speed on Polish railway is 160 km/h, although speed recordContinue reading “A 3 kV DC Electric Traction System Modernisation for Increased Speed and Trains Power Demand – Problems of Analysis and Synthesis”