On / Off – Board Chargers for Electric Vehicles

Published by Artur J. MORADEWICZ, Instytut Elektrotechniki Abstract. The element of infrastructure that provides a connection between an electric vehicle (EV) and a depleted battery and electric source that will charge/discharge these batteries is the Electric Vehicle Service Equipment (EVSE). Recently, the interest of electric vehicles and their charging infrastructure has been the subject ofContinue reading “On / Off – Board Chargers for Electric Vehicles”

Operation of Electrical Vehicles Fast Charging Stations in Warsaw – Case Study of InnogyGO! Collecting Point

Published by Krzysztof ZAGRAJEK, Konrad WRÓBLEWSKI(1), Piotr BICZEL(2), Łukasz SOSNOWSKI(3),Warsaw University of Technology, Institute of Electrical Power Engineering (1); Institute of Theory of Electrical Engineering, Measurement and Information Systems (2) ; Innogy Stoen Operator (3) Abstract. The paper presents the problems of operating a fast charging station for electric vehicles in a collecting point ofContinue reading “Operation of Electrical Vehicles Fast Charging Stations in Warsaw – Case Study of InnogyGO! Collecting Point”

Electrical Vehicle Impact on Distribution Network Power Quality

Published by Sampsa KUPARI, Metropolia, Helsinki University of Applied Sciences Abstract: The electrical vehicle form a huge load (and occasionally a generator as well) that is not resistive but possibly of nonlinear character. This may have an effect on distribution network power quality and possibly disturb seriously other consumers. If this is not taken careContinue reading “Electrical Vehicle Impact on Distribution Network Power Quality”

PQView Software System

Published by Electrotek Concepts, Inc. Background PQView® is a database software application developed and commercialized by Electrotek Concepts, Inc. (“Electrotek”), which is designed to store and analyze large quantities of power quality-related disturbance and steady-state measurement data. PQView enables users to organize data from a variety of instruments, such as power quality monitors, microprocessor relays,Continue reading “PQView Software System”

Power Factor Correction as the Right Step Towards a Safer Environment

Published by Alexander ABRAMOVITZ1, Volodymyr YASKIV2 , Keyue SMEDLEY3, Sami Shamoon College of Engineering (1), Ternopil Ivan Puluj National Technical University (2), University of California (3) Abstract. Generation and transfer of electrical energy can severely degrade the environment. The necessity of joint research in the field of high-frequency power converters with power factor correction toContinue reading “Power Factor Correction as the Right Step Towards a Safer Environment”

PQView Users Group Meeting October 25-26, 2022

Published by Electrotek Concepts, Inc. PQView® is a Microsoft Windows server application for collecting, processing, and building databases of electric power measurements. Developed in cooperation with EPRI®, PQView has evolved into a comprehensive system for centralizing data from many different types of metering systems including power quality monitors, digital fault recorders, microprocessor relays, and SCADAContinue reading “PQView Users Group Meeting October 25-26, 2022”

Distribution Substation Harmonic Measurement Data Evaluation

Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Substation Harmonic Measurement Data Evaluation, Document ID: PQS1016, Date: October 15, 2010. Abstract: This case study presents a distribution harmonic data analysis for a substation monitoring location for a three-month period. The utility substation included a step-down transformer and a number of distribution feeders that supplied aContinue reading “Distribution Substation Harmonic Measurement Data Evaluation”

Analysis of Lightning Current Distribution in the Lightning Protection System (LPS) with using Numerical Simulations

Published by Konrad SOBOLEWSKI, Warsaw University of Technology Abstract. The paper describes the numerical model of a typical lightning protection system (LPS). This model was used to get information’s about lightning current distributions as an effect of direct lightning strike to this protection system. To perform this task was chosen software MATLAB/SIMULINK. With this toolContinue reading “Analysis of Lightning Current Distribution in the Lightning Protection System (LPS) with using Numerical Simulations”

Efunity becomes PQSynergy & Power Quality Blog Gold Sponsor

We are pleased to announce that Efunity was a Golden Sponsor for PQSynergyTM Conference Exhibition 2022 and Power Quality Blog. It is a privilege to be supported by Efunity. We are grateful to Adrian Teo, Chief Executive Officer of Efunity and to the Efunity team. Efunity is a company based out of Singapore that offers turnkeyContinue reading “Efunity becomes PQSynergy & Power Quality Blog Gold Sponsor”

Harmonics Generation, Propagation and Purging Techniques in Non-Linear Loads

Published by Hadeed Ahmed Sher, Khaled E. Addoweesh and Yasin Khan 1. Introduction Industrial revolution has transformed the whole life with advanced technological improvements. The major contribution in the industrial revolution is due to the availability of electrical power that is distributed through electrical utilities around the world. The concept of power quality in thisContinue reading “Harmonics Generation, Propagation and Purging Techniques in Non-Linear Loads”