Industrial Facility IEEE Std. 519 Compliance Evaluation

Published by Electrotek Concepts, Inc., PQSoft Case Study: Industrial Facility IEEE Std. 519 Compliance Evaluation, Document ID: PQS1015, Date: October 15, 2010. Abstract: This case study presents an industrial facility IEEE Std. 519 harmonic compliance evaluation. The analysis included frequency response and harmonic distortion simulations for a substation and a single industrial customer with a numberContinue reading “Industrial Facility IEEE Std. 519 Compliance Evaluation”

Regulation of Current Harmonics in Grid with Dead-beat Controlled Shunt Active Power Filter

Published by Parandhaman BALAMURUGAN1, Natarajan SENTHIL KUMAR1,Vellore Institute of Technology (1),Chennai, Tamilnadu, India Abstract. Hardware implementation of Shunt Active Power Filter (SAPF) to regulate harmonics in the grid current is presented in this work. Dead-beat controller is employed to regulate the harmonics injected by SAPF using Spartan-6 FPGA processor. The effectiveness of the control strategyContinue reading “Regulation of Current Harmonics in Grid with Dead-beat Controlled Shunt Active Power Filter”

Power Quality Monitoring Part 2: Design Considerations for a Standards-Compliant Power Quality Meter

Published by Jose Mendi, EE Power – Technical Articles: Power Quality Monitoring Part 2: Design Considerations for a Standards-Compliant Power Quality Meter, May 18, 2023. This article explains how to efficiently design a standards-compliant power quality measurement instrument using a ready-to-use platform that accelerates development. It discusses solutions for designing Class A and Class S meters,Continue reading “Power Quality Monitoring Part 2: Design Considerations for a Standards-Compliant Power Quality Meter”

Implementing Electric Vehicles in Public Services: A Case Study Research

Published by João Reis, Department of Economics, Management, Industrial Engineering and Tourism, GOVCOPP, Aveiro University, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal. Email: reis.joao@ua.pt Abstract: In the last years, most European countries have developed strategies to implement the use of electric vehicles. This paper uses a qualitative case study research in the automotive industry toContinue reading “Implementing Electric Vehicles in Public Services: A Case Study Research”

Power Quality Monitoring Part 1: The Importance of Standards-Compliant Power Quality Measurements

Published by Jose Mendi, EE Power – Technical Articles: Power Quality Monitoring Part 1: The Importance of Standards-Compliant Power Quality Measurements, May 17, 2023. This article discusses the importance of power quality (PQ) measurements in today’s electric infrastructure and reviews areas of application for PQ monitoring. It will cover the IEC standard for power quality andContinue reading “Power Quality Monitoring Part 1: The Importance of Standards-Compliant Power Quality Measurements”

Electric Vehicles: A Data Science Perspective Review

Published by Dario Pevec *,† , Jurica Babic † and Vedran Podobnik †, Faculty of Electrical Engineering and Computing, University of Zagreb, Zagreb 10000, Croatia;jurica.babic@fer.hr (J.B.); vedran.podobnik@fer.hr (V.P.)* Correspondence: dario.pevec@fer.hr† These authors contributed equally to this work. Abstract: Current trends are showing that the popularity of electric vehicles (EVs) has significantly increased over the lastContinue reading “Electric Vehicles: A Data Science Perspective Review”

Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method

Published by Milan ŠIMKO1, Daniel KORENČIAK1, Miroslav GUTTEN1, Richard JANURA1,University of Zilina, Slovakia (1) Abstract. The first part of paper deals with the base information about diagnostics and analysis of transformer insulating system in time domain. The second part of paper deals with proposal measuring system of moisture analysis by return voltage method (RVM) forContinue reading “Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method”

How to Reduce the Soil’s Resistivity

Published by Lorenzo Mari, EE Power – Technical Articles: How to Reduce the Soil’s Resistivity, September 28, 2020. Lowering the resistance of a grounding electrode is not always enough to reduce the soil’s resistivity. Reducing the resistivity of the soil around the electrodes can help achieve adequate resistance to the ground. The elements that most affectContinue reading “How to Reduce the Soil’s Resistivity”

Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents

Published by Rafael ALIPIO, Renan SEGANTINI, Federal Centre of Technological Education of Minas Gerais Abstract. This paper assesses the transient distribution of potentials along a grounding grid subjected to currents representative of first and subsequent strokes. It is shown that the transient non-uniform distribution of potential along the grounding system may lead to the flowContinue reading “Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents”

Influence of Distributed Generation on Sectionalizing Switches Placement in MV Distribution Networks

Published by Wojciech BĄCHOREK1, Mariusz BENESZ1, AGH University of Science and Technology (1) Abstract. This paper presents the influence of distributed generation DG and reclosers placement on the reliability of distribution network. The brute force method and evolutionary algorithm were used to solve the optimization task. The placement of the switches was determined independently usingContinue reading “Influence of Distributed Generation on Sectionalizing Switches Placement in MV Distribution Networks”