Potential Transformer Operation, Applications and Accuracy

Published by Alex Roderick, EE Power – Technical Articles: Potential Transformer Operation, Applications and Accuracy, July 14, 2021. Learn about the operation and accuracy of potential transformers. The high voltages typically seen on power lines are a hazard to technicians working on or near the power lines. It is a difficult task to design a voltmeterContinue reading “Potential Transformer Operation, Applications and Accuracy”

Ferroresonance in Distribution Systems – State of the Art

Published by Mohamed M. EL-Shafhy1, Alaa M. Abdel-hamed1, Ebrahim A. Badran2,Electrical Power & Machines Department, High Institute of Engineering, El-Shorouk Academy, Cairo, Egypt (1), Electrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt (2) Abstract. Recently, there are increasing interest in studying the ferroresonance phenomenon, due to the various problems it causes to powerContinue reading “Ferroresonance in Distribution Systems – State of the Art”

On the Processing of Harmonics and Interharmonics: Using Hanning Window in Standard Framework

Published by A. Testa member IEEE, D. Gallo student member IEEE, R. Langella member IEEE Abstract: The harmonic and interharmonic analysis recommendations contained in the latest IEC standards on Power Quality are considered. The spectral leakage problems, due to synchronization errors of the analysed waveforms with the window widths adopted are analysed. Improvements of theContinue reading “On the Processing of Harmonics and Interharmonics: Using Hanning Window in Standard Framework”

Large Scale Proactive Power-Quality Monitoring: An Example from Australia

Published by Sean Elphick, Member, IEEE, Phil Ciufo, Senior Member, IEEE, Gerrard Drury, Vic Smith, Sarath Perera, Senior Member, IEEE, Vic Gosbell, Senior Member, IEEE, University of Wollongong. Abstract – In Australia and many other countries, distribution Network Service Providers (DNSPs) have an obligation to their customers to provide electrical power that is reliable andContinue reading “Large Scale Proactive Power-Quality Monitoring: An Example from Australia”

Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant

Published by Marian HYLA, Silesian University of Technology, Department of Power Electronics, Electrical Drives and Robotics. ORCID: 0000-0001-6466-7398 Abstract. The paper presents the issues of the influence on the supply electrical power grid of the thyristor rectifier supplying high power receivers such as a shaft hoisting machines in mining. The current distortion influence of theContinue reading “Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant”

Medium Voltage Switching Transient Induced Potential Transformer Failures; Prediction, Measurement and Practical Solutions

Published by Daniel McDermit1, David D. Shipp2, Thomas J. Dionise3, Visuth Lorch4,1Sr. Project Manager Turner Construction Company Chicago, IL2PE Eaton Electrical Group Power Systems Engineering Warrendale, PA Fellow, IEEE3PE Eaton Electrical Group Power Systems Engineering Warrendale, PA Senior Member, IEEE4Eaton Electrical Group Power Systems Engineering Warrendale, PA Abstract— During commissioning of a large data center,Continue reading “Medium Voltage Switching Transient Induced Potential Transformer Failures; Prediction, Measurement and Practical Solutions”

Impact of Electric Vehicle Charging Station on Power Quality

Published by M. S. Arjun1, N. Mohan1, K. R. Sathish2, Arunkumar Patil3, G. Thanmayi4.1Department of Electrical and Electronics Engineering, JSS Science and Technology University, Mysore, India2Department of Electrical and Electronics Engineering, ATME College of Engineering, Mysore, India3Department of Electrical Engineering, Central University of Karnataka, Kalaburagi (Gulbarga), India4M. Tech-Energy System and Management, Department of Electrical andContinue reading “Impact of Electric Vehicle Charging Station on Power Quality”

EDP Distribuição’s Development of Support Tools and Platforms for Power Quality Management and Analysis

Published by Fabrice GONÇALVES, António LEBRE, Pedro VELOSO, Fernando BASTIÃO, Nuno MELO, DP Distribuição – Portugal. Emails: fabrice.goncalves@edp.pt, antoniojose.lebrecardoso@edp.pt, pedro.veloso@edp.pt, fernando.bastiao@edp.pt, nuno.melo@edp.pt 24th International Conference & Exhibition on Electricity Distribution (CIRED). 12-15 June 2017. ABSTRACT EDP Distribuição, as distribution system operator (DSO), has been developing an ambitious Power Quality (PQ) monitoring program. This paper aimsContinue reading “EDP Distribuição’s Development of Support Tools and Platforms for Power Quality Management and Analysis”

Harmonic Measurement and Analysis during Electric Vehicle Charging

Published by Mohd Zamri Che Wanik1, Mohd FadzilMohd Siam1, Afida Ayob2, Subiyanto2, Azah Mohamed2, Abu HanifahAzit3, SaharuddinSulaiman3, Mohamed Azrin Mohamed Ali4, Zahrul Faizi Hussein1, Ahmad Kamil MatHussin1, 1TNB Research Malaysia, Malaysia, 2Power System Research Group, Universiti Kebangsaan Malaysia, Malaysia, 3TNB Distribution Malaysia, Malaysia, 4Malaysian Green Technology Corporation, Bandar BaruBangi, Malaysia. Email: mzamri@tnbr.com.my ABSTRACT This paperContinue reading “Harmonic Measurement and Analysis during Electric Vehicle Charging”

A Review of the Harmonic and Unbalance Effects in Electrical Distribution Networks due to EV Charging

Published by Lauri Kütt, Eero Saarijärvi, Matti Lehtonen, Department of Electrical Engineering Aalto University School of Electrical Engineering, Espoo, Finland. lauri.kutt@aalto.fi, eero.saarijarvi@aalto.fiHeigo Mõlder, Jaan Niitsoo, Department of Electrical Engineering, Tallinn University of Technology Tallinn, Estonia Abstract—For wide use of electric vehicles (EVs), there are different aspects of the electric power system to consider for makingContinue reading “A Review of the Harmonic and Unbalance Effects in Electrical Distribution Networks due to EV Charging”