Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation

Published by Hana’ A. Rabab’ah 1, Yaser N. Anagreh2, Al-Ahliyya Amman University (1), Yarmouk University (2) ORCID: 1. 0000-0002-1581-7721; 2. 0000-0002-3826-9262 Abstract. This paper presents an integrated stand-alone wind / Photovoltaic (PV) system enhanced with storage system and the required controllers. The proposed scheme concerned with maximum electrical power extracting from the two renewable energyContinue reading “Stand-alone Hybrid System for Extracting Maximum Power and Constant Voltage under Load Variation”

Novel Fault Current Limiter for Voltage Sag Compensation of Point of Common Coupling

Published by SARAGADAM HEMANTH KUMAR, SH SURESH KUMAR BUDI, Dept. of EEE, Gokul Group of Institutions, Piridi, Bobbili, AP, India. Abstract: Voltage sag is one of the most common power quality disturbances in electrical networks. Voltage sags are incidents that reduce the voltage amplitude for a short time. Voltage Sags are caused by abrupt increasesContinue reading “Novel Fault Current Limiter for Voltage Sag Compensation of Point of Common Coupling”

A Case Study of Sharing the Harmonic Voltage Distortion Responsibility between the Utility and the Consumer

Published by F. H. Costa, I. N. Santos, S. F. P. Silva and J. C. de Oliveira, Group of Power Quality Faculty of Electrical Engineering Federal University of Uberlandia Campus Santa Monica – Av. João Naves de Ávila, 2100 Uberlandia (Brazil). Phone/Fax number:+55 (34) 3239-4733, e-mail: fernandahein@hotmail.com, ivan.ufu@gmail.com, sergio@qes.com.br, jcoliveira@ufu.br Abstract. The aim of thisContinue reading “A Case Study of Sharing the Harmonic Voltage Distortion Responsibility between the Utility and the Consumer”

Semi-Analytic Calculations of Overvoltages caused by Direct Lightning Strike in Buried Coaxial Cable

Published by Karol ANISEROWICZ, Renata MARKOWSKA, Bialystok University of Technology Abstract. Results of calculations of overvoltages caused by a direct lightning strike to an underground coaxial cable are presented. Analytic formulas are used in the frequency domain. The time-domain waveforms are computed using the Inverse Discrete Fourier Transform (IDFT). Streszczenie. Przedstawiono wyniki obliczeń przepięć spowodowanychContinue reading “Semi-Analytic Calculations of Overvoltages caused by Direct Lightning Strike in Buried Coaxial Cable”

Three-phase Four-wire Circuits Interpretation by Means of Different Power Theories

Published by Fernando P. MARAFÃO1, Eduardo V. LIBERADO1, Helmo K. M. PAREDES2, Luiz C. P. da SILVA2, Unesp – Univ Estadual Paulista (1), University of Campinas (2) Abstract. In order to contribute to the discussion of defining a generalized power theory, valid for unbalanced and non linear circuits, this paper discusses the relationship and discrepanciesContinue reading “Three-phase Four-wire Circuits Interpretation by Means of Different Power Theories”

Power System Harmonics

Published by Olutayo Ogunyemi, School of Science and Engineering, Atlantic International University, Honolulu, HI. Abstract – Good power quality is essential in electrical power network. Power quality is not limited to availability of supply but also include steady frequency value and voltage magnitude and smooth waveform characteristics of the supply (Ogheneovo Johnson, 2016).The present situationContinue reading “Power System Harmonics”

A Review of Harmonics Detection and Measurement in Power System

Published by 1. Dnyaneshwar D. Ahire, Professor, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India.2. Snehal R. Durdhavale Student, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India. ABSTRACT – A load is said to be “linear” when it draws a currentContinue reading “A Review of Harmonics Detection and Measurement in Power System”

Assessment of Flange Diffuser Structures to Improve the Power Generation of a Diffuser Augmented Wind Turbine

Published by 1. Yiyin KLISTAFANI, 2. A. M. Shiddiq YUNUS, 3. Muhammad ANSHAR, 4. Sri SUWASTI, State Polytechnic of Ujung Pandang, Indonesia (1) ORCID: 1. 0000-0003-3064-9612; 2. 0000-0002-9599-6941; 3. 0000-0001-5687-5023; 4. 0000-0002-7070-9651 Abstract. Wind energy has become the most popular renewable based power plant for the last decades due to its environment benighted and largeContinue reading “Assessment of Flange Diffuser Structures to Improve the Power Generation of a Diffuser Augmented Wind Turbine”

A New Technique to Detect Harmonic Sources in Polluted Power Systems

Published by Pietro Vincenzo Barbaro, Antonio Cataliotti, Valentina Cosentino, Salvatore Nuccio, Dipartimento di Ingegneria Elettrica, Elettronica e delle Telecomunicazioni, Università di Palermo, Palermo, Italy. E-mails: barbaro@diepa.unipa.it, acataliotti@ieee.org, cosentino@diepa.unipa.it, nuccio@unipa.it Abstract: This paper presents a comparative analysis among different nonactive power quantities proposed in literature in nonsinusoidal conditions; with respect to this, a new single-point approachContinue reading “A New Technique to Detect Harmonic Sources in Polluted Power Systems”

Elspec becomes PQSynergy™ & Power Quality Blog Sponsor

We are pleased to announce that Elspec was a Sponsor for PQSynergyTM International and Conference Exhibition 2024 and Power Quality Blog. It is a privilege to be supported by Elspec. We are grateful to the Elspec team. Elspec is a leading global provider of advanced power quality analyzers, power quality solutions and power monitoring software.Continue reading “Elspec becomes PQSynergy™ & Power Quality Blog Sponsor”