A New Application of Vector Based Current Regulator for STATCOM to Improve Dynamic Performance of DFIG

Published by A. M. Shiddiq YUNUS1, Ahmed Abu-SIADA2, Mohammad A.S. MASOUM3, State Polytechnic of Ujung Pandang, Indonesia (1), Curtin University, Australia (2), Utah Valley University , USA (3) Abstract. Wind turbine generator (WTG) installation has been rapidly growing globally in the last few years. In the year of 2017, the WTG installation has reached aContinue reading “A New Application of Vector Based Current Regulator for STATCOM to Improve Dynamic Performance of DFIG”

Researchers Achieve Higher Voltage PV With Inverter System

Published by Jake Hertz, EE Power – News: Researchers Achieve Higher Voltage PV With Inverter System, November 13, 2023. A team of researchers claims to cut cable requirements by 700 kg of copper per kilometer of cable with a higher voltage inverter system for photovoltaics. In photovoltaic (PV) systems, reducing cable size is essential for economicContinue reading “Researchers Achieve Higher Voltage PV With Inverter System”

Analysis of the Influence of Unequal Current Distribution on the Heating of Parallel Connected LV MOV Surge Arresters

Published by Bartłomiej SZAFRANIAK, Paweł ZYDROŃ, and Łukasz FUŚNIK, AGH University of Science and Technology, Krakow, Poland Abstract. In low-voltage (LV) electrical networks metal-oxide varistor (MOV) surge arresters connected in parallel are often used against overvoltages. The paper presents the results of laboratory experiments, during which pairs of parallel connected MOV surge arresters were subjectedContinue reading “Analysis of the Influence of Unequal Current Distribution on the Heating of Parallel Connected LV MOV Surge Arresters”

Thailand Integrates Large-Scale Wind Farms

Published by C. MADTHARAD, Provincial Electricity Authority (PEA), Thailand. and J. WARMAN, Senergy Econnect Australia. T&D World – Renewables: Thailand Integrates Large-Scale Wind Farms, Sept. 28, 2015. Provincial Electricity Authority address power-quality issues that arise from increasing penetration of renewable energy. In the Kingdom of Thailand, power-quality regulations applicable to small power producers and veryContinue reading “Thailand Integrates Large-Scale Wind Farms”

Potential Transformer Operation, Applications and Accuracy

Published by Alex Roderick, EE Power – Technical Articles: Potential Transformer Operation, Applications and Accuracy, July 14, 2021. Learn about the operation and accuracy of potential transformers. The high voltages typically seen on power lines are a hazard to technicians working on or near the power lines. It is a difficult task to design a voltmeterContinue reading “Potential Transformer Operation, Applications and Accuracy”

Ferroresonance in Distribution Systems – State of the Art

Published by Mohamed M. EL-Shafhy1, Alaa M. Abdel-hamed1, Ebrahim A. Badran2,Electrical Power & Machines Department, High Institute of Engineering, El-Shorouk Academy, Cairo, Egypt (1), Electrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt (2) Abstract. Recently, there are increasing interest in studying the ferroresonance phenomenon, due to the various problems it causes to powerContinue reading “Ferroresonance in Distribution Systems – State of the Art”

On the Processing of Harmonics and Interharmonics: Using Hanning Window in Standard Framework

Published by A. Testa member IEEE, D. Gallo student member IEEE, R. Langella member IEEE Abstract: The harmonic and interharmonic analysis recommendations contained in the latest IEC standards on Power Quality are considered. The spectral leakage problems, due to synchronization errors of the analysed waveforms with the window widths adopted are analysed. Improvements of theContinue reading “On the Processing of Harmonics and Interharmonics: Using Hanning Window in Standard Framework”

Large Scale Proactive Power-Quality Monitoring: An Example from Australia

Published by Sean Elphick, Member, IEEE, Phil Ciufo, Senior Member, IEEE, Gerrard Drury, Vic Smith, Sarath Perera, Senior Member, IEEE, Vic Gosbell, Senior Member, IEEE, University of Wollongong. Abstract – In Australia and many other countries, distribution Network Service Providers (DNSPs) have an obligation to their customers to provide electrical power that is reliable andContinue reading “Large Scale Proactive Power-Quality Monitoring: An Example from Australia”

Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant

Published by Marian HYLA, Silesian University of Technology, Department of Power Electronics, Electrical Drives and Robotics. ORCID: 0000-0001-6466-7398 Abstract. The paper presents the issues of the influence on the supply electrical power grid of the thyristor rectifier supplying high power receivers such as a shaft hoisting machines in mining. The current distortion influence of theContinue reading “Higher Harmonics Filtration in the Power Supply System of Thyristor Hoisting Machine of Shaft Transport in a Mining Plant”

Medium Voltage Switching Transient Induced Potential Transformer Failures; Prediction, Measurement and Practical Solutions

Published by Daniel McDermit1, David D. Shipp2, Thomas J. Dionise3, Visuth Lorch4,1Sr. Project Manager Turner Construction Company Chicago, IL2PE Eaton Electrical Group Power Systems Engineering Warrendale, PA Fellow, IEEE3PE Eaton Electrical Group Power Systems Engineering Warrendale, PA Senior Member, IEEE4Eaton Electrical Group Power Systems Engineering Warrendale, PA Abstract— During commissioning of a large data center,Continue reading “Medium Voltage Switching Transient Induced Potential Transformer Failures; Prediction, Measurement and Practical Solutions”