Published by Michael B. Marz, American Transmission Company, Waukesha, WI Email: mmarz@atcllc.com INTRODUCTION The use of sophisticated power electronics and communication systems to improve power system efficiency, flexibility and reliability is increasing interharmonic distortion and adding equipment sensitive to that distortion to the system. Knowledge of interharmonics, their sources, effects, measurement, limits and mitigation, willContinue reading “Interharmonics: What They Are, Where They Come From and What They Do”
Yearly Archives: 2023
Arc Flash and Overvoltage Protection
Published by Alex Roderick, EE Power – Technical Articles: Arc Flash and Overvoltage Protection, August 26, 2021. In addition to the risk of electrical shock, other hazards are present when work is performed on or near energized electrical equipment or conductors. Two serious hazards are electrical arc flashes and electrical arc blasts. An arc flash isContinue reading “Arc Flash and Overvoltage Protection”
How to Improve Resistance to Ground
Published by Lorenzo Mari, EE Power – Technical Articles: How to Improve Resistance to Ground, September 25, 2020. Learn about the methods used to lower the resistance of a grounding electrode When the soil resistivity is high, and the resistance to ground exceeds the required values, specific techniques are useful to decrease it. This article evaluatesContinue reading “How to Improve Resistance to Ground”
Essential Indicators of Harmonic Distortion and Measurement Principles
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Essential indicators of harmonic distortion and measurement principles A number of indicators are used to quantify and evaluate the harmonic distortion in current and voltage waveforms, namely: • Power factor• Crest factor• Harmonic spectrum• R.m.s. value These indicators are indispensable in determining any necessaryContinue reading “Essential Indicators of Harmonic Distortion and Measurement Principles”
Operating Assessment of Local Power Grid Development Considered Captive Power Plant and Expanding Structure
Published by Arif Nur AFANDI1,2,3, Irham FADLIKA1, Langlang GUMILAR1, Takeshi HIYAMA4 1Electrical Engineering, Universitas Negeri Malang, Malang, Indonesia 2Center for Advanced Materials for Renewable Energy, Universitas Negeri Malang, Malang, Indonesia3Smart Power and Advanced Energy Systems Research Center, Batu, Jawa Timur, Indonesia4The IROAST, Kumamoto University, Kumamoto, Japan Abstract. Based on current developments related to the applicationContinue reading “Operating Assessment of Local Power Grid Development Considered Captive Power Plant and Expanding Structure”
Industrial Harmonic Filter Design
Published by Electrotek Concepts, Inc., PQSoft Case Study: Industrial Harmonic Filter Design, Document ID: PQS0504, Date: June 30, 2005. Abstract: The industrial harmonic problem can be solved using a comprehensive approach including site surveys, harmonic measurements, and computer simulations. Simple calculations are used to determine the system resonant frequencies and then the preliminary model development isContinue reading “Industrial Harmonic Filter Design”
System and Equipment Grounding Safety
Published by Alex Roderick, EE Power – Technical Articles: System and Equipment Grounding Safety, August 15, 2021. Grounding is used to provide a safe path for a fault current to flow. Grounding is an integral part of any properly operating electrical system. In residence, grounding protects the occupants by providing a safe pathway for unwanted electricityContinue reading “System and Equipment Grounding Safety”
Definition and Origin of Harmonics
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Definition and origin of harmonics Definition of Harmonics The presence of harmonics in electrical systems means that current and voltage are distorted and deviate from sinusoidal waveforms. Harmonic currents are caused by non-linear loads connected to the distribution system. A load is said toContinue reading “Definition and Origin of Harmonics”
Single-point and Multi-point Signal Grounding
Published by Lorenzo Mari, EE Power – Technical Articles: Single-point and multi-point Signal Grounding, April 16, 2021. A grounding arrangement must be designed and implemented adequately for the electronic equipment’s proper performance Introduction The main categories for grounding electronic equipment are: • Safety ground (AC and DC power ground) prevents shocks and fire hazards from theContinue reading “Single-point and Multi-point Signal Grounding”
Assessment of the Impact of Photovoltaic System on the Power Quality in the Distribution Network
Published by Marek GAŁA, Andrzej JĄDERKO, Czestochowa University of Technology, Faculty of Electrical Engineering Abstract. The paper offers a characteristic of a photovoltaic (PV) system with the function UPS, equipped with energy storage AQUION ENERGY Battery 25 kWh and a system for monitoring and management of energy flow. Results and their analysis is presented forContinue reading “Assessment of the Impact of Photovoltaic System on the Power Quality in the Distribution Network”