Analysis of the Impact of Secondary Winding Impedance on the Parameters of Transformer Type Superconducting Current Limiters

Published by Joanna KOZIEŁ, Lublin University of Technology, Institute of Electrical Engineering and Electrotechnologies Abstract. The paper presents the classification of superconducting fault current limiters. In particular the principle of construction and operations of superconducting current limiter of transformer type is presented. Functional physical model of such a limiter, designed, manufactured in the Laboratory ofContinue reading “Analysis of the Impact of Secondary Winding Impedance on the Parameters of Transformer Type Superconducting Current Limiters”

Making Sense of Electric Vehicle Charging Options

Published by Mike Falter, EE Power – Market Insights: Making Sense of Electric Vehicle Charging Options, September 07, 2022. When it comes to charging your electric vehicle there are several options to consider based on speed, convenience and cost. In the recent article on the Wallbox acquisition of COIL, EE Power briefly reviewed the Wallbox portfolio of EV chargingContinue reading “Making Sense of Electric Vehicle Charging Options”

Computer Assisted Harmonics Analysis

Published by Prof. Silviu Darie, PhD (EE), Technical University Cluj Napoca, Romania, Honorary Member of the Romanian Technical Sciences Academy. Email: silviu.darie@enm.utcluj.ro. Abstract: Based on the author’s experience one describes in field tested methodologies which can be employed in solving the frequency-based power quality problems. A generic approach is presented and an experience-based assessment isContinue reading “Computer Assisted Harmonics Analysis”

Single Line to Ground-Fault Detection for Unit Generator-Transformer based on Wavelet Transform and Neutral Networks

Published by Ahmad Rizal SULTAN1, Mohd Wazir bin MUSTAFA2, Makmur SAINI3, Ahmad GAFFAR41,3,4 Politeknik Negeri Ujung Pandang, South Sulawesi-Indonesia2Universiti Teknologi Malaysia, Faculty of Electrical Engineering, Johor-Malaysia Abstract. The aim of this paper is to detect the single line to ground fault on the unit generator- transformer. A new ground fault detection scheme based on theContinue reading “Single Line to Ground-Fault Detection for Unit Generator-Transformer based on Wavelet Transform and Neutral Networks”

Charging Infrastructure and Testing of the Electric Vehicle Energy Battery Decline

Published by Anna ZIELIŃSKA, AGH University of Science and Technology Abstract: The article presents the infrastructure for charging electric vehicles, their development and the types and methods of charging. The paper presents the results of testing the level of vehicle charge depending on the route traveled and its dynamics. The test results show the changeContinue reading “Charging Infrastructure and Testing of the Electric Vehicle Energy Battery Decline”

Solar Power Plant with Distributed System of PV Panels

Published by Mariusz ŚWIDERSKI, Michał GWÓŹDŹ, Poznan University of Technolog Abstract. In the work the other approach to a photovoltaic system is presented. With regard to an improvement of reliability of a solar system, maintaining and improving system’s efficiency, authors proposed conception of the distributed PV system. This system consists of a set of individualContinue reading “Solar Power Plant with Distributed System of PV Panels”

Trends in Electric Vehicle Fast Charging

Published by Rakesh Kumar, EE Power – Technical Articles: Trends in Electric Vehicle Fast Charging, February 02, 2023. Ultra-fast charging methodology, ultra-fast charging station architectures, and improved battery technology are some promising trends for fast-charging electric vehicles. EVs hold the potential for decarbonizing the transportation sector. But the crucial impediment to the adoption of electrified transportationContinue reading “Trends in Electric Vehicle Fast Charging”

Prediction of Electricity Production in Island Operation under the different Wind Generation Modes

Published by Dušan MEDVEĎ1, Zsolt ČONKA1 Marek PAVLIK1, Ján ZBOJOVSKY1,Michal KOLCUN1,Michal IVANČÁK1, Technical University of Košice, Department of Electric Power Engineering, Mäsiarska 74, 04001 Košice, Slovakia (1) Abstract. This paper deals with the prediction of electricity generation in particular part of the network (island operation) where were considered various regimes of the wind power plantContinue reading “Prediction of Electricity Production in Island Operation under the different Wind Generation Modes”

Overvoltage Induced in Overhead Power Lines by nearby Lightning Stroke

Published by Grzegorz MASŁOWSKI, Robert ZIEMBA, Tomasz KOSSOWSKI,Rzeszow University of Technology Abstract. The results of simulations of overvoltages induced in the overhead transmission line, caused by nearby lightning stroke are presented. Calculations were made using the LIOV module implemented in the EMTP-RV program. The influence of the distance of the lightning channel from the lineContinue reading “Overvoltage Induced in Overhead Power Lines by nearby Lightning Stroke”

Noise and Vibration Analysis of a Distribution Transformer

Published by Dániel MARCSA, eCon Engineering Kft., Hungary Abstract. Transformer noise is a significant contribution to unwanted ambient noise, especially in the vicinity of the electrical transmission facility. It is therefore very important to get to know the mechanism of noise generation of the distribution transformer. As outcomes of this work, a finite element basedContinue reading “Noise and Vibration Analysis of a Distribution Transformer”