Published by Grzegorz WĘGRZYN1, Robert SZCZYGIEŁ,AGH2, University of Science and Technology. ORCID: 1. 0000-0002-4132-4939; 2. 0000-0001-6342–0107 Abstract. This paper presents a concept of noised signal voltage measurement using noise distribution. The goal of this project was to work out a new solution for low noise, hybrid pixel detectors that work in single photon counting mode.Continue reading “Voltage Measurements Using Noise Distribution”
Tag Archives: Voltage
Autotransformers for Power Systems
Published by Waldemar ZIOMEK, PTI Manitoba Inc., Winnipeg, MB, Canada Abstract. When the primary and secondary voltages are obtained from the same winding, or from two windings which are galvanically connected, such a transformer is called an autotransformer. The paper will focus on fundamentals, design and applications of autotransformers of core-type design. The selected problemsContinue reading “Autotransformers for Power Systems”
Application of Additional Grounded Wires in High Voltage Overhead Power Lines to Reduce the Intensity of Electric Field Generated by Phase Wires
Pubsliehd by Jacek GUMIELA1, Dariusz SZTAFROWSKI1 Politechnika Wrocławska, Katedra Energoelektryki (1) Abstract. To minimize interference with the environment it is important to make every effort already at the design stage to spare the trouble associated with additional investment later on. Due to the value of land in urban areas, it is beneficial to take necessaryContinue reading “Application of Additional Grounded Wires in High Voltage Overhead Power Lines to Reduce the Intensity of Electric Field Generated by Phase Wires”
Electric Utility Harmonic Study Medium Voltage Filter Design
Published by Electrotek Concepts, Inc., PQSoft Case Study: Electric Utility Harmonic Study Medium Voltage Filter Design, Document ID: PQS0407, Date: September 30, 2004. Abstract: This particular utility was experiencing voltage distortion levels throughout their distribution network that were exceeding IEEE Std. 519 limits. One customer, a plastic extrusion plant, was experiencing blown fuses in their switchedContinue reading “Electric Utility Harmonic Study Medium Voltage Filter Design”
Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method
Published by Milan ŠIMKO1, Daniel KORENČIAK1, Miroslav GUTTEN1, Richard JANURA1,University of Zilina, Slovakia (1) Abstract. The first part of paper deals with the base information about diagnostics and analysis of transformer insulating system in time domain. The second part of paper deals with proposal measuring system of moisture analysis by return voltage method (RVM) forContinue reading “Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method”
A Review on Voltage Control Methods for Active Distribution Networks
Published by Tengku Juhana TENGKU HASHIM1, Azah MOHAMED2, Hussain SHAREEF3, Universiti Kebangsaan Malaysia Abstract. Power distribution systems are in the state of transition from passive to active networks due to the rising penetration level of distributed generators (DGs). One of the technical challenges of active networks is to maintain an acceptable voltage level. This problemContinue reading “A Review on Voltage Control Methods for Active Distribution Networks”
PWM Drive Motor Failures due to Transient Voltages
Published by Electrotek Concepts, Inc., PQSoft Case Study: PWM Drive Motor Failures due to Transient Voltages, Document ID: PQS0404, Date: June 30, 2004. Abstract: In an effort to improve the efficiency of many industrial processes, equipment has been retrofitted with adjustable speed drives (ASDs). The ASDs allow for better speed control, soft starting of motors, andContinue reading “PWM Drive Motor Failures due to Transient Voltages”
Study of 345 kV Transient Recovery Voltages
Published by Electrotek Concepts, Inc., PQSoft Case Study: Study of 345 kV Transient Recovery Voltages, Document ID: PQS0602, Date: January 1, 2006. Abstract: Transient recovery voltage (TRV) is the voltage across the terminals of a pole of circuit breaker following current zero when interrupting faults. TRV waveshapes can be oscillatory, exponential, cosine-exponential or combinations of theseContinue reading “Study of 345 kV Transient Recovery Voltages”
Electric Arc Furnace Modeling for Voltage Flicker Evaluation
Published by Electrotek Concepts, Inc., PQSoft Case Study: Electric Arc Furnace Modeling for Voltage Flicker Evaluation, Document ID: PQS0313, Date: April 16, 2003. Abstract: A steel manufacturer is planning to add a second arc furnace to their existing facility. Concerns are raised as to whether the additional furnace will cause levels of voltage flicker that mightContinue reading “Electric Arc Furnace Modeling for Voltage Flicker Evaluation”
What is Voltage Drop Study and Analysis
Published by Carelabs, Carelabs is authorized provider of Electrical Installation’s Study, Analysis, Inspection, and Certification services in UAE, and offer voltage drop study and analysis services. Website: carelabz.com Dynamic voltage (IR) drop, in contrast to the static voltage drop depends on the switching activity of the design, and hence it is vector dependent. Designing an ideal powerContinue reading “What is Voltage Drop Study and Analysis”