Harmonic Information Management System

Published by 1. Johan ADOLFSSON, Director, Unipower AB, ja@unipower.se, 2. Peter ANDERSSON, CEO, Unipower AB, psa@unipower.se, 3. Nilesh CHINTALWAR, GM, PCI Ltd, nilesh@prime-pci.in, 4. Shital SHAH, PCI Ltd, shitalshah@prime-pci.in INTRODUCTION In the vast majority of countries today there are regulations and standards implemented that specify the maximum level of harmonic content. Some countries implement theContinue reading “Harmonic Information Management System”

Power System Harmonics

Published by Olutayo Ogunyemi, School of Science and Engineering, Atlantic International University, Honolulu, HI. Abstract – Good power quality is essential in electrical power network. Power quality is not limited to availability of supply but also include steady frequency value and voltage magnitude and smooth waveform characteristics of the supply (Ogheneovo Johnson, 2016).The present situationContinue reading “Power System Harmonics”

A Review of Harmonics Detection and Measurement in Power System

Published by 1. Dnyaneshwar D. Ahire, Professor, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India.2. Snehal R. Durdhavale Student, Matoshri College of Engineering and Research Centre, Nashik Savitribai Phule Pune University, Nashik, Maharashtra, India. ABSTRACT – A load is said to be “linear” when it draws a currentContinue reading “A Review of Harmonics Detection and Measurement in Power System”

Power Quality Analysis for Light-Duty Electric Vehicles: A Case Study in Malta

Published by Kris Scicluna 1,* , Brian Azzopardi 1,2 and Kurt Spiteri 1,(1) Institute of Engineering & Transport, Malta College of Arts, Science and Technology, PLA 9032 Paola, Malta; brian.azzopardi@mcast.edu.mt (B.A.)(2) The Foundation for Innovation and Research—Malta, BKR 4012 Birkirkara, Malta*Correspondence: kris.scicluna@mcast.edu.mt; Tel.: +356-7986-8731 Abstract: This paper presents a power quality analysis for multiple electricContinue reading “Power Quality Analysis for Light-Duty Electric Vehicles: A Case Study in Malta”

Total Harmonic Distortion (THD) and Power Factor Calculation

Published by Alex Roderick, EE Power – Technical Articles: Total Harmonic Distortion (THD) and Power Factor Calculation, May 10, 2021. In this article, we will discuss how to measure total harmonic distortion and the power factor calculations utilized. Total harmonic distortion (THD) is the amount of harmonics on a line compared to the line fundamental frequency,Continue reading “Total Harmonic Distortion (THD) and Power Factor Calculation”

Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP

Published by Zia Hameed1, Muhammad Rafay Khan Sial2, Adnan Yousaf3, Muhammad Usman Hashmi,Faculty of Engineering and Technology, Superior University, 17-km off Raiwind Road Lahore PakistanEmails: zia.hameed@superior.edu.pk, rafay.khan@superior.edu.pk, adnan.yousaf@superior.edu.pk Abstract—Power System Harmonics is a real point of concern for Electrical Engineers. In power systems, non-linear loads are permanently connected, unlike transients and other distortions are produced.Continue reading “Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP”

Computer Assisted Harmonics Analysis

Published by Prof. Silviu Darie, PhD (EE), Technical University Cluj Napoca, Romania, Honorary Member of the Romanian Technical Sciences Academy. Email: silviu.darie@enm.utcluj.ro. Abstract: Based on the author’s experience one describes in field tested methodologies which can be employed in solving the frequency-based power quality problems. A generic approach is presented and an experience-based assessment isContinue reading “Computer Assisted Harmonics Analysis”