Published by Jake Hertz, EE Power – News: Researchers Achieve Higher Voltage PV With Inverter System, November 13, 2023. A team of researchers claims to cut cable requirements by 700 kg of copper per kilometer of cable with a higher voltage inverter system for photovoltaics. In photovoltaic (PV) systems, reducing cable size is essential for economicContinue reading “Researchers Achieve Higher Voltage PV With Inverter System”
Tag Archives: Renewable Energy
Thailand Integrates Large-Scale Wind Farms
Published by C. MADTHARAD, Provincial Electricity Authority (PEA), Thailand. and J. WARMAN, Senergy Econnect Australia. T&D World – Renewables: Thailand Integrates Large-Scale Wind Farms, Sept. 28, 2015. Provincial Electricity Authority address power-quality issues that arise from increasing penetration of renewable energy. In the Kingdom of Thailand, power-quality regulations applicable to small power producers and veryContinue reading “Thailand Integrates Large-Scale Wind Farms”
Power Exchange in Smart Grids Integrating Renewable Energy
Published by MEKKAOUI Ali1, LAOUER Mohammed2, YOUNES Mimoun1, University of Sidi Belabes, Algeria (1), University Center of Naama, Algeria (2) Abstract. Smart grids are essentially characterized by reliability and energy efficiency so we can optimize the performance of the electrical system to ensure safe and reliable operation. This paper discusses smart grids in a futureContinue reading “Power Exchange in Smart Grids Integrating Renewable Energy”
Global Trends of Photovoltaic Energy Usage
Published by Lucjan KURZAK, Building Construction Faculty Czestochowa University of Technology, Poland Abstract. The market of photovoltaics is one of the most dynamically developing sectors of world economy. From the standpoint of the environment, the energy of solar radiation is the most attractive source. Both new materials and technological solutions, growing effectiveness of conversion ofContinue reading “Global Trends of Photovoltaic Energy Usage”
Energy Sector of Pakistan – A Review
Published by Rana Muneeb Hassan, Andrzej Bie´n, Szymon Barczentewicz, Mohammad Abu Sarha, AGH University of Science and Technology Abstract. Any country’s socio-economic growth is interlinked with number of factors, some of more significance with devastating impact whereas the others with very less impact. Amongst all such factors, energy is one of the major player inContinue reading “Energy Sector of Pakistan – A Review”
Specifics of Hydropower Plant Management in Isolated Power Systems
Published by Sherkhon SULTONOV1 , Murodbek SAFARALIEV2 , Sergey KOKIN2 , Stepan DMITRIEV2 , Inga ZICMANE3 , Shokhin DZHURAEV1,4 Tajik Technical University, Tajikistan(1), Ural Federal University (2), Riga Technical University, Latvia (3), Branch of the National Research University ‘Moscow Power Engineering Institute’ in Dushanbe City (4)ORCID: 1. 0000-0003-2322-5272; 2. 0000-0003-3433-9742; 3. 0000-0001-7493-172X; 4. 0000-0001-8781-2383; 5.Continue reading “Specifics of Hydropower Plant Management in Isolated Power Systems”
Harmonic Estimation on a Transmission System with Large-Scale Renewable Energy Sources
Published by Saheed Lekan GBADAMOSI1, Nnamdi NWULU1, O.M. BABATUNDE2,Dept. of Electrical & Electronics Engineering Science, University of Johannesburg, South Africa (1), University of Lagos, Nigeria (2) Abstract. This paper presents a modelling and simulation approach using the Electrical Transient Analyzer Program software to evaluate the magnitude and effects of harmonics from varying RES into theContinue reading “Harmonic Estimation on a Transmission System with Large-Scale Renewable Energy Sources”
Optimization of the Wind Farm Structure through the use of PV Installations and the use of Pumped Storage Power Plants
Published by Joanna KOZIEŁ1, Michał MAJKA1, Andrzej WAC- WŁODARCZYK1, Krzysztof NAGLAK2,Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology(1), Faculty of Electrical Engineering and Computer Science, Lublin University of Technology(2),ORCID: 1. 0000-0003-1682-2589, 2. 0000-0002-7153-040X 3. 0000-0002-6272-9249 Abstract. The article presents methods of wind farm optimization through the useContinue reading “Optimization of the Wind Farm Structure through the use of PV Installations and the use of Pumped Storage Power Plants”
Energy Generation Through Wind Power Systems
Published by Alex Roderick, EE Power – Technical Articles: Energy Generation Through Wind Power Systems, August 21, 2021. Because winds are primarily caused by uneven heating effects of the sun, wind energy is considered to be an indirect form of solar energy and is therefore renewable. The primary cause of winds is the uneven heating ofContinue reading “Energy Generation Through Wind Power Systems”
Power Flow Forecasts: A Status Quo Review. Part 1: RES Generation Prediction
Published by Marcin KOPYT, Warsaw University of Technology, Electrical Power Engineering Institute Abstract. In recent years, rising electricity demand accompanied by CO2 reduction targets has dramatically increased RES penetration into power systems, giving rise to the need to estimate power production and demand to properly manage power infrastructure. This paper is Part 1 of anContinue reading “Power Flow Forecasts: A Status Quo Review. Part 1: RES Generation Prediction”