Case Study for Obtaining Power Quality Grid-Code Compliance

Published by Dirk A. J. van der Bank, and Kyle Lass, Energize, July 2018 The practical implications of obtaining power quality (PQ) grid-code compliance for category C photovoltaic (PV) renewable power plants (RPP) are described in this article. Successful harmonic mitigation was implemented via means of the installation of active harmonic filters (AHF) at lowContinue reading “Case Study for Obtaining Power Quality Grid-Code Compliance”

Analysis of the Impact of a Wind Farm on the Quality of Electricity in the Distribution Grid

Published by Joanna KOZIEŁ, Grzegorz KOMARZYNIEC, Andrzej WAC-WŁODARCZYK, Ryszard GOLEMAN, Department of Electrical Engineering and Electrotechnologies, Lublin University of Technology Abstract. The article presents the characteristics of the net power of a wind farm as a function of wind speed, and lists the factors determining the selection of a wind farm. Classification of large windContinue reading “Analysis of the Impact of a Wind Farm on the Quality of Electricity in the Distribution Grid”

Optimization of the Reliability of Power Electric Distribution Grids MV with the use of Heuristic Algorithms

Published by Wojciech NITA1, Sylwester FILIPIAK2, PGE Dystrybucja S.A. Oddział Skarżysko-Kamienna (1), Politechnika Świętokrzyska (2) Abstract — The article aims to present the application of selected heuristic algorithms to improve the reliability indices of MV distribution grids. Improving the reliability and efficiency of power distribution grids is currently a topical and important issue. The paperContinue reading “Optimization of the Reliability of Power Electric Distribution Grids MV with the use of Heuristic Algorithms”

EDP Distribuição’s Development of Support Tools and Platforms for Power Quality Management and Analysis

Published by Fabrice GONÇALVES, António LEBRE, Pedro VELOSO, Fernando BASTIÃO, Nuno MELO, DP Distribuição – Portugal. Emails: fabrice.goncalves@edp.pt, antoniojose.lebrecardoso@edp.pt, pedro.veloso@edp.pt, fernando.bastiao@edp.pt, nuno.melo@edp.pt 24th International Conference & Exhibition on Electricity Distribution (CIRED). 12-15 June 2017. ABSTRACT EDP Distribuição, as distribution system operator (DSO), has been developing an ambitious Power Quality (PQ) monitoring program. This paper aimsContinue reading “EDP Distribuição’s Development of Support Tools and Platforms for Power Quality Management and Analysis”

The Quality of Electric Power Supplied into the Grid by Co-Generation Units

Published by Jiri JANSA, Petr MOLDRIK, Daniel MINARIK, VSB – Technical University of Ostrava Abstract. This paper deals with the utilisation of firedamp for combined heat and electric power generation. The firedamp is gained from hard-coal mines and can be combusted in a co-generation units with gas-engine. This process involves more efficient utilisation of firedamp.Continue reading “The Quality of Electric Power Supplied into the Grid by Co-Generation Units”

Measurement Practices for Reliability and Power Quality: Appendix D and E

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Measurement Practices for Reliability and Power Quality: Appendix D and E”

Part 9 Markets and the Provision of Basic Service

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 9 Markets and the Provision of Basic Service”

Part 8 Standardizing Reliability and Power Quality Metrics

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 8 Standardizing Reliability and Power Quality Metrics”

Part 7 Valuing Reliability

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 7 Valuing Reliability”

Part 6 Pitfalls in Methods for Reliability Index Calculation

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 6 Pitfalls in Methods for Reliability Index Calculation”