Published by Szymon ROGOWSKI1, Maciej SIBIŃSKI2, Karol GARLIKOWSKI3, Katedra Przyrządów Półprzewodnikowych i Optoelektronicznych, Politechnika Łódzka, ORCID. 1. 0000‐0002‐1279‐3592, 2. 0000‐0002‐9752‐3400 Abstract. The following article presents results of measurements and parameter comparison of energy bank based on supercapacitor batteries and a typical lead-acid solution designed for PV microinstallation. For the purposes of the research, basic measurementsContinue reading “Applications of Supercapacitor Systems in Photovoltaic Installations”
Tag Archives: PV Systems
Optimization of the Wind Farm Structure through the use of PV Installations and the use of Pumped Storage Power Plants
Published by Joanna KOZIEŁ1, Michał MAJKA1, Andrzej WAC- WŁODARCZYK1, Krzysztof NAGLAK2,Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology(1), Faculty of Electrical Engineering and Computer Science, Lublin University of Technology(2),ORCID: 1. 0000-0003-1682-2589, 2. 0000-0002-7153-040X 3. 0000-0002-6272-9249 Abstract. The article presents methods of wind farm optimization through the useContinue reading “Optimization of the Wind Farm Structure through the use of PV Installations and the use of Pumped Storage Power Plants”
Power Flow Forecasts: A Status Quo Review. Part 1: RES Generation Prediction
Published by Marcin KOPYT, Warsaw University of Technology, Electrical Power Engineering Institute Abstract. In recent years, rising electricity demand accompanied by CO2 reduction targets has dramatically increased RES penetration into power systems, giving rise to the need to estimate power production and demand to properly manage power infrastructure. This paper is Part 1 of anContinue reading “Power Flow Forecasts: A Status Quo Review. Part 1: RES Generation Prediction”
Solar Energy and LED Technologies for Street Lighting Demand Side Management SLDSM
Published by Aziz HAFFAF*1, Fatiha LAKDJA1,2, Rachid MEZIANE1, Djaffar OULD ABDESLAM3Electro-Technical Engineering Laboratory, Faculty of Technology, Saida University, Algeria (1) Sidi-Bel-Abbes University, Algeria (2) IRIMAS laboratory, Haute Alsace University, Mulhouse, France (3) Abstract. In this research paper, solar energy and LED technologies as a street lighting demand side management SLDSM option are carried out. TheContinue reading “Solar Energy and LED Technologies for Street Lighting Demand Side Management SLDSM”
Harmonics From Solar PV Inverters
Published by Muhammad Najmi Bohari, P.Eng, powerquality.sg THE ABCS OF POWER QUALITY IN SINGAPORE, October 14, 2023. In general, current harmonics contribution from solar PV inverters do not pose much of a power quality problem. Its ITHD is usually small and negligible as compared to a harmonics-producing load such as a variable speed drive (ITHDContinue reading “Harmonics From Solar PV Inverters”
Causes and Solutions of the Potential Induced Degradation (PID) Effect in PV Modules
Published by Pietro Tumino, EE Power – Technical Articles: Causes and Solutions of the Potential Induced Degradation (PID) Effect in PV Modules, July 09, 2020. In case you are dealing with unexpected and unreasonable power loss in your photovoltaic plant, you may be experiencing the PID effect in the PV modules. Potential induced degradation (PID)Continue reading “Causes and Solutions of the Potential Induced Degradation (PID) Effect in PV Modules”
Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems
Published by Paweł PIJARSKI, Sylwester ADAMEK, Robert JĘDRYCHOWSKI, Klara SEREJA, Lublin University of Technology, Department of Electrical Networks and Security Abstract. An increasing number of connected prosumer installations, mainly photovoltaic ones, can cause problems with the operation of lowvoltage networks such as voltage fluctuations. These problems can be solved by an adequate control of theContinue reading “Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems”
Selected Aspects of Photovoltaic Power Station Operation in the Power System
Published by Andrzej LANGE1, Marian PASKO2University of Warmia and Mazury, Department of Electrical and Power Engineering, Electronics and Automation (1), Silesian University of Technology, Institute of Electrical Engineering and Computer Science (2) Abstract. This paper presents the results of a five-year study of a 1 MW photovoltaic power station in the Warmia and Mazury Province.Continue reading “Selected Aspects of Photovoltaic Power Station Operation in the Power System”
Solar Power Plant with Distributed System of PV Panels
Published by Mariusz ŚWIDERSKI, Michał GWÓŹDŹ, Poznan University of Technolog Abstract. In the work the other approach to a photovoltaic system is presented. With regard to an improvement of reliability of a solar system, maintaining and improving system’s efficiency, authors proposed conception of the distributed PV system. This system consists of a set of individualContinue reading “Solar Power Plant with Distributed System of PV Panels”
Comparison of PV Plant Energy Generation Prediction Tools with Measured Data
Published by Igor PETROVIĆ1, Zdenko ŠIMIĆ2, Mario VRAŽIĆ2,Technical College in Bjelovar (1), University of Zagreb, Faculty of Electrical Engineering and Computing (2) Abstract. The object of this research is to compare three of the most popular conventional analytical models used for estimation of electrical energy production of photovoltaic panels. From this analysis a single modelContinue reading “Comparison of PV Plant Energy Generation Prediction Tools with Measured Data”