Published by Bashir Mahdi EBRAHIMI1, Jawad FAIZ1, Mohammad ETEMADREZAIE2, Mojtaba BABAIE3, Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran(1), Department of electrical and computer engineering, Delft, Zuid-holland, Netherlands(2), Faculty of Engineering, Science and Research Campus, Islamic Azad University, Tehran, Iran(3) Abstract. Impacts of load variationContinue reading “Eccentricity Fault Identification in Round Rotor Synchronous Motors considering Load Variation”
Tag Archives: Electrical Fault
Frequency Resolution Improvements in Induction Motor Fault Diagnosis : Experimental Validation
Published by Ameur Fethi AIMER1, Ahmed Hamida BOUDINAR2, Mohamed Amine KHODJA2, Azeddine BENDIABDELLAH2, University of Saida. Algeria (1), University of Sciences and Technology of Oran. Algeria (2) ORCID: 1. 0000-0003-4933-109X Abstract. Induction machines are enjoying growing interest mainly due to their robustness, their weight to power ratio and their manufacturing cost. However, several faults affectContinue reading “Frequency Resolution Improvements in Induction Motor Fault Diagnosis : Experimental Validation”
Analysis of Development Directions of Online Diagnostics of Synchronous Generator
Published by Olena RUBANENKO1, Sree Lakshmi GUNDEBOMMU2, Iryna HUNKO3, Zdenek PEROUTKA1, Regional Innovational Center at the Faculty of Electrical Engineering University of West Bohemia (1), Plzen, Czech Republic CVR College of Engineering Mangalpalli (2), Hyderabad, India Vinnytsia National Technical University (3), Vinnytsia, Ukraine Abstract. In this paper the analysis of online diagnostics of synchronous generationsContinue reading “Analysis of Development Directions of Online Diagnostics of Synchronous Generator”
Static Synchronous Compensator and Superconducting Fault Current Limiter for Power Transmission System Transient Stability Regulation Including Wind Generator
Published by Abdelkrim ZEBAR, Department of Electrical Engineering, Faculty of technology, Ferhat Abbas Setif 1 University, Setif, Algeria Abstract. The increase of environmental pollution and the decreasing of the energy is extremely related to social progress. The resolution of the environment pollution depends on renewable energy such as wind energy system. Though, that system isContinue reading “Static Synchronous Compensator and Superconducting Fault Current Limiter for Power Transmission System Transient Stability Regulation Including Wind Generator”
Impedance-Differential Relay as a Transmission Line Fault Locator
Published by Justyna HERLENDER, Jan IŻYKOWSKI, Eugeniusz ROSOŁOWSKI, Wroclaw University of Science and Technology, Department of Electrical Power Engineering Abstract. This paper deals with analysis of impedance-differential protection applied to locating faults on power transmission line. Based on the voltage and current measurements at both line ends, the differential impedance is calculated. It enables toContinue reading “Impedance-Differential Relay as a Transmission Line Fault Locator”
Excitation Type and Results of Simulated Electric Field Distribution in MV Cable Termination
Published by Maciej CIUBA1, Michał WOJCIECHOWSKI1, Maciej OWSIŃSKI2, Michał BORECKI1,Warsaw University of Technology, Koszykowa 75, 00-662 Warszawa, Poland (1)Institute of Power Engineering – Research Institute, Mory 8, 01-330 Warszawa, Poland (2) Abstract. The presented article discusses the differences in the results of the electric field simulation in a medium voltage heat-shrinkable cable termination with theContinue reading “Excitation Type and Results of Simulated Electric Field Distribution in MV Cable Termination”
Impacts of Fault Diagnosis Schemes on Distribution System Reliability
Published by Shahram Kazemi, Member, IEEE, Matti Lehtonen, and Mahmud Fotuhi-Firuzabad, Senior Member, IEEE.IEEE TRANSACTIONS ON SMART GRID, VOL. 3, NO. 2, JUNE 2012 Abstract—Design and development of fault diagnosis schemes (FDS) for electric power distribution systems are major steps in realizing the self-healing function of a smart distribution grid. The application of the FDSContinue reading “Impacts of Fault Diagnosis Schemes on Distribution System Reliability”
Statistical Analysis and Modeling of the Reliability of Overhead Low Voltage Lines
Published by Łukasz GRĄKOWSKI, Andrzej Ł. CHOJNACKI, Katarzyna GĘBCZYK, Kornelia BANASIK Kielce University of Technology, Faculty of Electrical Engineering, Automatic Control and Computer Science Abstract: The paper present a thorough analysis of seasonality and causes of failures of low voltage overhead lines. Such lines are mainly characteristic of rural areas. An average duration of failures,Continue reading “Statistical Analysis and Modeling of the Reliability of Overhead Low Voltage Lines”
Differential Relay Protection for Prototype Transformer
Published by Bashar M. SALIH, Mohammed A. IBRAHIM, Ali N. HAMOODI, Northern Technical University Abstract. This paper represents the differential protection relay that used to protect the prototype-Terco power transformer. Matlab/Simulink is used to simulate the protection system. The power differential protection algorithm has been simulated and tested on a 2KVA power transformer under differentContinue reading “Differential Relay Protection for Prototype Transformer”
Inter-Turns Short Circuits in Stator Winding of Squirrel-Cage Induction Motor
Published by Maciej ANTAL, Wrocław University of Science and Technology, Department of Electrical Machines, Drives and Measurements Abstract. A physical model of a squirrel-cage induction drive, allowing to stimulate coil short circuits in the front part of the motor, was used to investigate the phenomena accompanying short circuits. Assuming that a short circuit occurs duringContinue reading “Inter-Turns Short Circuits in Stator Winding of Squirrel-Cage Induction Motor”