Published by Blue Sea Systems Inc., website: http://www.bluesea.com There are two potential failures in a boat’s electrical system that can put people on or around the boat at risk of lethal electric shock. Understanding Equipment Leakage Circuit Interrupters (ELCIs) and Ground Fault Circuit Interrupters (GFCIs) to make your boat safer. In a properly functioning marineContinue reading “AC Ground Faults, the Boater, and ABYC—Understanding Equipment Leakage Circuit Interrupters (ELCIs) and Ground Fault Circuit Interrupters (GFCIs) to make your boat safer.”
Tag Archives: Electrical Fault
Case Studies on Ground-Fault Protection of Microgrid Power Systems with Diverse Power Sources
Published by Dirk Danninger IEEE Member Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163, USAScott Manson Senior Member, IEEE Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163, USAFernando Calero IEEE Member Schweitzer Engineering Laboratories, Inc. 2350 NE Hopkins Court Pullman, WA 99163, USACeeman Vellaithurai Senior Member, IEEE Schweitzer EngineeringContinue reading “Case Studies on Ground-Fault Protection of Microgrid Power Systems with Diverse Power Sources”
The Dangers of Stray Current Damage in Electrical Systems & Arc Flash Protection
Published by Jim Galloway, International Association of Electrical Inspectors (IAEI) Magazine, Electrical Fundamentals – The Dangers of Stray Current Damage in Electrical Systems & Arc Flash Protection, July 3, 2019 The new extension to the factory is finally finished. The engineers have produced a state-of-the-art design; the qualified electricians have completed a professional installation withContinue reading “The Dangers of Stray Current Damage in Electrical Systems & Arc Flash Protection”
Electrical Shock and its Effects
Published by Alex Roderick, EE Power – Technical Articles: Electrical Shock and its Effects, August 17, 2021. Anyone working on electrical equipment should have respect for all voltages, have knowledge of the principles of electricity, and follow safe work procedures. An electrical shock occurs when a body becomes a part of an electrical circuit. The effectsContinue reading “Electrical Shock and its Effects”
Case Study on Fault Analysis Using PMU
Published by Prithwish Mukhopadhyay, General Manager, prithwish.mukhopadhyay@posoco.in,Rajkumar Anumasula, Senior Engineer, rajkumar@posoco.in, Abhimanyu Gartia, Deputy General Manager, agartia@posoco.in, Chandan Kumar, Engineer, chandan.wrldc@posoco.in, Pushpa Seshadri, Chief Manager, pushpa_seshadri@posoco.in, Sunil Patil, Engineer, skpatil@posoco.in , WRLDC, Mumbai, India Abstract — Synchrophasors are used extensively in Indian Grid to detect and analyze faults occurring in the system. This paper majorlyContinue reading “Case Study on Fault Analysis Using PMU”
AC Equipment Grounding: Creating a Safe Fault Current Path to Ground
Published by Lorenzo Mari, EE Power – Technical Articles: AC Equipment Grounding: Creating a Safe Fault Current Path to Ground, August 07, 2020. Learn about the merits of the equipment grounding to protect people in faulted AC power systems. Electrical equipment casings should be at earth potential under normal conditions. When a fault occurs in anContinue reading “AC Equipment Grounding: Creating a Safe Fault Current Path to Ground”
Arc Flash and Overvoltage Protection
Published by Alex Roderick, EE Power – Technical Articles: Arc Flash and Overvoltage Protection, August 26, 2021. In addition to the risk of electrical shock, other hazards are present when work is performed on or near energized electrical equipment or conductors. Two serious hazards are electrical arc flashes and electrical arc blasts. An arc flash isContinue reading “Arc Flash and Overvoltage Protection”
Ground Fault Protection Methods of a Generator Stator
Published by Ahmad Rizal SULTAN, Mohd Wazir bin MUSTAFA, Technology University of Malaysia, Faculty of Electrical Engineering Abstract. The type of generator grounding method and the system configuration determine the choice of ground fault protection. Ground fault generator stator can cause serious damage to the generator. Therefore, the total area of the generator stator windingsContinue reading “Ground Fault Protection Methods of a Generator Stator”
Failure Duration in Distribution Networks
Published by Martin SLIVKA, Radomír GOŇO, Stanislav RUSEK, VŠB-Technical University of Ostrava Abstract. The paper deals with statistical analysis of data on faults and failures in electrical power distribution. We used the statistical analysis of both MV overhead and cable lines, and electrical power stations of one distribution company. The data were collected from 2000Continue reading “Failure Duration in Distribution Networks”
The Coreless Superconducting Fault Current Limiter 15 kV 140 A
Published by Michał MAJKA, Janusz KOZAK, Electrotechnical Institute Abstract. The superconducting fault current limiter (SFCL) is a device allowing for a more effective use of the existing power network infrastructure. The limitation of short-circuit currents by the SFCL to safe levels will result in the network elements being susceptible to smaller electrodynamic and thermal overloads.Continue reading “The Coreless Superconducting Fault Current Limiter 15 kV 140 A”