Regulation of Current Harmonics in Grid with Dead-beat Controlled Shunt Active Power Filter

Published by Parandhaman BALAMURUGAN1, Natarajan SENTHIL KUMAR1,Vellore Institute of Technology (1),Chennai, Tamilnadu, India Abstract. Hardware implementation of Shunt Active Power Filter (SAPF) to regulate harmonics in the grid current is presented in this work. Dead-beat controller is employed to regulate the harmonics injected by SAPF using Spartan-6 FPGA processor. The effectiveness of the control strategyContinue reading “Regulation of Current Harmonics in Grid with Dead-beat Controlled Shunt Active Power Filter”

Implementing Electric Vehicles in Public Services: A Case Study Research

Published by João Reis, Department of Economics, Management, Industrial Engineering and Tourism, GOVCOPP, Aveiro University, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal. Email: reis.joao@ua.pt Abstract: In the last years, most European countries have developed strategies to implement the use of electric vehicles. This paper uses a qualitative case study research in the automotive industry toContinue reading “Implementing Electric Vehicles in Public Services: A Case Study Research”

Electric Vehicles: A Data Science Perspective Review

Published by Dario Pevec *,† , Jurica Babic † and Vedran Podobnik †, Faculty of Electrical Engineering and Computing, University of Zagreb, Zagreb 10000, Croatia;jurica.babic@fer.hr (J.B.); vedran.podobnik@fer.hr (V.P.)* Correspondence: dario.pevec@fer.hr† These authors contributed equally to this work. Abstract: Current trends are showing that the popularity of electric vehicles (EVs) has significantly increased over the lastContinue reading “Electric Vehicles: A Data Science Perspective Review”

Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method

Published by Milan ŠIMKO1, Daniel KORENČIAK1, Miroslav GUTTEN1, Richard JANURA1,University of Zilina, Slovakia (1) Abstract. The first part of paper deals with the base information about diagnostics and analysis of transformer insulating system in time domain. The second part of paper deals with proposal measuring system of moisture analysis by return voltage method (RVM) forContinue reading “Measuring and Diagnostic System for Analysis of Transformer Insulation by Return Voltage Method”

Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents

Published by Rafael ALIPIO, Renan SEGANTINI, Federal Centre of Technological Education of Minas Gerais Abstract. This paper assesses the transient distribution of potentials along a grounding grid subjected to currents representative of first and subsequent strokes. It is shown that the transient non-uniform distribution of potential along the grounding system may lead to the flowContinue reading “Electromagnetic Disturbances Propagation Along a Grounding Grid Subjected to Lightning Currents”

Influence of Distributed Generation on Sectionalizing Switches Placement in MV Distribution Networks

Published by Wojciech BĄCHOREK1, Mariusz BENESZ1, AGH University of Science and Technology (1) Abstract. This paper presents the influence of distributed generation DG and reclosers placement on the reliability of distribution network. The brute force method and evolutionary algorithm were used to solve the optimization task. The placement of the switches was determined independently usingContinue reading “Influence of Distributed Generation on Sectionalizing Switches Placement in MV Distribution Networks”

Methods for Determining Power Losses in Cable Lines with Non-Linear Load

Published by Łukasz TOPOLSKI, Jurij WARECKI, Zbigniew HANZELKA, AGH University of Science and Technology Abstract. Harmonic currents in power cables cause additional power losses associated with phenomena that increase the temperature of the cable insulation and make its service life shorter. For these reasons, it is important to choose methods for determining active power losses,Continue reading “Methods for Determining Power Losses in Cable Lines with Non-Linear Load”

The Influence of Power Supply Network Inductance on the HTS Transformer Inrush Current

Published by Grzegorz KOMARZYNIEC1, The Lublin University of Technology, Institute of Electrical Engineering and Electrotechnologies (1) Abstract. The HTS transformer inrush current may lead to thermal damage its windings made of HTS 2G tapes. The parameters affecting the value and duration of the inrush current are: the impedance of the transformer windings and the impedanceContinue reading “The Influence of Power Supply Network Inductance on the HTS Transformer Inrush Current”

Improved Control Strategy of Wind Energy Conversion System with PMSG during Low Voltage Sags

Published by Piotr GAJEWSKI, Wrocław University of Science and Technology, Department of Electrical Machines, Drives and Measurements Abstract. The paper presents the improved control strategy for Wind Energy Conversion System (WECS) during voltage sags. The considered back-to-back converter system includes: Ma-chine Side Converter (MSC) and Grid Side Converter (GSC) with control circuits. To the windContinue reading “Improved Control Strategy of Wind Energy Conversion System with PMSG during Low Voltage Sags”

Example of Inrush Current Elimination After Connection of High Input DC Voltage

Published by Jakub KELLNER1, Michal PRAZENICA2, Department of Mechatroncs and Electronics, Faculty of Electrical and Information Technology, University of Zilina, Slovakia Abstract. This article deals with the problem of elimination inrush currents. The document proposes an active method for limiting the inrush currents during circuit switching when high inrush currents occur. The proposed system limitsContinue reading “Example of Inrush Current Elimination After Connection of High Input DC Voltage”