Published by Sudhakiran Ponnuru1, Ashok Kumar R1, Jothi Swaroopan NM2, Annamalai University (1), RMK Engineering College (2), India ORCID: 1. 0000-0002-5345-5709, 2. 0000-0001-6994-7591, 3. 0000-0001-7671-5190 Abstract. Renewable sources creates new opportunity when it is integrated with the microgrid increasing the energy efficiency of the system. This paper focuses on the adaptive control strategies which utilizesContinue reading “Switching Strategies of Single Stage Battery based Microgrid”
Tag Archives: Wind Turbines
A New Application of Vector Based Current Regulator for STATCOM to Improve Dynamic Performance of DFIG
Published by A. M. Shiddiq YUNUS1, Ahmed Abu-SIADA2, Mohammad A.S. MASOUM3, State Polytechnic of Ujung Pandang, Indonesia (1), Curtin University, Australia (2), Utah Valley University , USA (3) Abstract. Wind turbine generator (WTG) installation has been rapidly growing globally in the last few years. In the year of 2017, the WTG installation has reached aContinue reading “A New Application of Vector Based Current Regulator for STATCOM to Improve Dynamic Performance of DFIG”
Thailand Integrates Large-Scale Wind Farms
Published by C. MADTHARAD, Provincial Electricity Authority (PEA), Thailand. and J. WARMAN, Senergy Econnect Australia. T&D World – Renewables: Thailand Integrates Large-Scale Wind Farms, Sept. 28, 2015. Provincial Electricity Authority address power-quality issues that arise from increasing penetration of renewable energy. In the Kingdom of Thailand, power-quality regulations applicable to small power producers and veryContinue reading “Thailand Integrates Large-Scale Wind Farms”
Optimization of the Wind Farm Structure through the use of PV Installations and the use of Pumped Storage Power Plants
Published by Joanna KOZIEŁ1, Michał MAJKA1, Andrzej WAC- WŁODARCZYK1, Krzysztof NAGLAK2,Department of Electrical Engineering and Electrotechnology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology(1), Faculty of Electrical Engineering and Computer Science, Lublin University of Technology(2),ORCID: 1. 0000-0003-1682-2589, 2. 0000-0002-7153-040X 3. 0000-0002-6272-9249 Abstract. The article presents methods of wind farm optimization through the useContinue reading “Optimization of the Wind Farm Structure through the use of PV Installations and the use of Pumped Storage Power Plants”
Energy Generation Through Wind Power Systems
Published by Alex Roderick, EE Power – Technical Articles: Energy Generation Through Wind Power Systems, August 21, 2021. Because winds are primarily caused by uneven heating effects of the sun, wind energy is considered to be an indirect form of solar energy and is therefore renewable. The primary cause of winds is the uneven heating ofContinue reading “Energy Generation Through Wind Power Systems”
Power Flow Forecasts: A Status Quo Review. Part 1: RES Generation Prediction
Published by Marcin KOPYT, Warsaw University of Technology, Electrical Power Engineering Institute Abstract. In recent years, rising electricity demand accompanied by CO2 reduction targets has dramatically increased RES penetration into power systems, giving rise to the need to estimate power production and demand to properly manage power infrastructure. This paper is Part 1 of anContinue reading “Power Flow Forecasts: A Status Quo Review. Part 1: RES Generation Prediction”
Voltage Fluctuations in Networks with Distributed Power Sources
Published by Maciej MRÓZ1, Zbigniew HANZELKA, Krzysztof CHMIELOWIEC2, TAURON Dystrybucja S.A.(1), AGH – University of Science and Technology (2) Abstract. One of the electromagnetic disturbances generated by distributed power sources, e.g. wind turbines, are voltage fluctuations. An imprecise prediction of the disturbance level may be the reason for erroneous decisions made at the stage ofContinue reading “Voltage Fluctuations in Networks with Distributed Power Sources”
Power Quality Experimental Research at the Primorsky Wind Power Station
Published by Yuriy SAYENKO1, Ryszard PAWEŁEK2, Andrii MOLCHAN1, Ewa DYKA2, Pryazovskyi State Technical University (1)Lodz University of Technology, Institute of Electrical Power Engineering (2) Abstract. The article presents results of experimental studies of power quality indicators conducted at the wind farm with 52 DFIG wind turbines with a unit capacity of 3.8 MW by GeneralContinue reading “Power Quality Experimental Research at the Primorsky Wind Power Station”
Selection Criteria and Analysis of Wind Turbines for DHW
Published by Artur NEMŚ, Magdalena NEMŚ, Adam RUZIEWIC, Wroclaw University of Science and Technology, Poland Abstract. The article describes the method and criteria of selecting wind turbines used to heat domestic hot water (DHW). The authors describe a method of choosing turbines based on power characteristics, climatic conditions and heating demands of a building. PowerContinue reading “Selection Criteria and Analysis of Wind Turbines for DHW”
An Experimental Study of Wind Data of a Wind Farm in Kosovo
Published by Sabrije OSMANAJ1, Bukurie HOXHA2, Rexhep SELIMAJ2*1Faculty of Electrical and Computer Engineering, , 2Faculty of Mechanical Engineering, University of Pristina, Republic of Kosovo Abstract. In Kosovo, 97% of energy is generated from lignite-fired power plants. Apart from the energy generation, the combustion process emits around 8000 ktCO2/yr and 1.5 Mt of ash in theContinue reading “An Experimental Study of Wind Data of a Wind Farm in Kosovo”