Published by Robert CZECHOWSKI, Politechnika Wrocławska, Katedra Elektroenergetyki Abstract. Smart Grid is both a concept and a way to mitigate infrastructural deficiencies and counteract the effects of the growing demand for electrical energy. One of the ways ensuring an increase in power grid’s management efficiency is utilization of the latest communication solutions. Such solutions ensureContinue reading “Security Policy and Good Practice for Implementation of Smart Grid Solutions”
Tag Archives: Smart Metering
Possibilities of Using Blockchain Technology in the Area of Electricity Trade Settlements
Published by Anna ZIELIŃSKA AGH University of Science and Technology, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering. ORCID. 0000-0002-2889-1488 Abstract: The article describes the advantages and possibilities of using blockchain in various areas and sectors of the economy related to electricity trade and trading. The aim of the article is to presentContinue reading “Possibilities of Using Blockchain Technology in the Area of Electricity Trade Settlements”
A Home Energy Management Algorithm in Demand Response Events for Household Peak Load Reduction
Published by Maytham S. AHMED1,2 Azah MOHAMED1 , Raad Z. HOMOD3 , and Hussain SHAREEF4, Dept. of Electrical, Electronic & System Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (1)General Directorate of Electrical Energy Production- Basrah, Ministry of electricity, Iraq (2)Dept. of Oil and Gas Engineering, Basrah University for Oil and Gas, 61004Continue reading “A Home Energy Management Algorithm in Demand Response Events for Household Peak Load Reduction”
Low-Cost and Accuracy Smart Meter Prototype for Smart Grids
Published by 1. Rafael GIVANILDO, 2. Denis LIMA, 3. Paulo PARIS, 4. Emerson PEDRINODepartment of Computer Science, Federal University of Sao Carlos, Sao Carlos, Brazil ORCID: 1. 0000-0003-1372-6049, 2. 0000-0002-0457-2562, 3. 0000-0001-8915-8215, 4. 0000-0003-3734-3202 Abstract. This article aims to carry out a brief bibliographical review on the main concepts related to Smart Grid, in additionContinue reading “Low-Cost and Accuracy Smart Meter Prototype for Smart Grids”
Model of Smart Electricity Meter
Published by Marek PAWŁOWSKI, Piotr BORKOWSKI, Bartosz BALSAM, Lodz University of Technology, Department of Electrical Apparatus Abstract. This paper presents the concepts of smart electricity grids with particular emphasis on aspects of the metering of customers through the implementation of smart meters. On the basis of the literature study, an analysis of the scope ofContinue reading “Model of Smart Electricity Meter”
Active Consumers in Smart Grid Systems – Applications of the Building Automation Technologies
Published by Marian NOGA1, Andrzej OŻADOWICZ1, Jakub GRELA1, Grzegorz HAYDUK1, AGH Akademia Górniczo-Hutnicza, Wydział Elektrotechniki, Automatyki, Informatyki i Inżynierii Biomedycznej (1) Abstract. The Building Automation Systems (BAS) fulfil an increasingly important role in buildings, especially commercial and public buildings. They are an essential element of the building management systems (BMS) organization, integrating all building infrastructureContinue reading “Active Consumers in Smart Grid Systems – Applications of the Building Automation Technologies”
Measurement of Power Characteristics in Public Lighting Networks
Published by Peter JANIGA, Dionýz GAŠPAROVSKÝ, Slovak University of Technology in Bratislava Abstract. The aim of this paper is to share the results of measurements in public lighting networks of current status in terms of electrical characteristics. Based on the measurements it is possible to create an image of the actual power proportions in publicContinue reading “Measurement of Power Characteristics in Public Lighting Networks”
Electricity Measurement Accuracy in the Smart Metering System
Publishing by Paweł WĘGIEREK, Michał KONARSKILublin University of Technology, Faculty of Electrical Engineering and Computer Science, Lublin, Poland Abstract. The smart metering to the power system implementation significantly changes the way of measurements and settlements in the electricity sector. This paper presents an analysis of realized measurement accuracy and the key information about the smartContinue reading “Electricity Measurement Accuracy in the Smart Metering System”