Published by Andrzej Ł. Chojnacki, Kielce University of Technology, Department of Power EngineeringORCID: 0000-0002-9227-7538 Abstract. The article presents the influence of weather conditions, represented by the ambient temperature, for the intensity of the failure of MV overhead power lines. It presents the mechanisms of damaging the equipment by the high and low temperatures. It showsContinue reading “Impact of Ambient Temperature on the Failure Intensity of Overhead MV Power Lines”
Tag Archives: Safety/Protection
Improving the Operation Characteristics of Non-Insulated Overhead Power Lines
Published by 1. Oleksandr KOZLOVSKYI1, 2. Dmitro TRUSHAKOV1, 3. Oleksandr SAVCHENKO2, 4. Serhiy RENDZINYAK3, 5. Vasyl KORUD3, Central Ukrainian National Technical University (1), Kharkiv Petro Vasylenko National Technical University of Agriculture (2), Lviv Polytechnic National University (3)ORCID: 1.0000-0001-6885-5994; 2.0000-0003-0326-2383, 3.0000-0002-6401-0852, 4.0000-0003-4544-4871, 5.0000-0002-1289-3534 Abstract. Methods of protection of wires of overhead power lines of group “anti-icing”Continue reading “Improving the Operation Characteristics of Non-Insulated Overhead Power Lines”
Test Stand for Testing and Diagnostics of Medium Voltage Vacuum Interrupters
Published by Paweł WĘGIEREK, Michał LECH, Lublin University of Technology, Faculty of Electrical Engineering and Computer Science Abstract. The article presents the detailed construction and capabilities of a research station for the diagnosis and testing of vacuum interrupters used in medium voltage electrical switching devices. The correct functioning of the stand has been confirmed byContinue reading “Test Stand for Testing and Diagnostics of Medium Voltage Vacuum Interrupters”
An Introduction to Transformer Harmonic Current Derating Metrics
Published by Richard Lam, CHK Power Quality Pty Ltd. Website: http://www.chkpowerquality.com.au Abstract. Transformer harmonic current derating metrics; Harmonic Loss Factor, K-Factor, and Factor K are introduced, and used to calculate derating factors for dry and oil-filled type transformers. Introduction The introduction of Switched Mode Power Supplies (SMPS) in office equipment and LED lighting, Variable Frequency/SpeedContinue reading “An Introduction to Transformer Harmonic Current Derating Metrics”
Problems of the Current State of Power Quality and Proposals for their Solution
Published by Lidiya Kovernikova, Melentiev Energy Systems Institute of the Siberian Branch of the Russian Academy of Sciences, Irkutsk, Russian Federation. Email: kovernikova@isem.irk.ru Abstract. The power quality in Russian electrical networks does not meet the requirements of regulatory documents. Big problems occur in all areas of people’s lives for this reason. Economic damage is oneContinue reading “Problems of the Current State of Power Quality and Proposals for their Solution”
Application of Electronic Load Circuit for Electrical Safety by using a Serial Mode Comparator
Published by Saktanong WONGCHAROEN1, Sansak DEEON1, Narong MUNGKUNG2, Pathumwan Institute of Technology, Thailand (1), King Mongkut’s University of Technology Thonburi, Thailand (2) Abstract. This research presented an electronic load circuit for electrical safety by using a serial mode comparator as a protection device against surges caused by electrical power lacking stability and quality. The applicationContinue reading “Application of Electronic Load Circuit for Electrical Safety by using a Serial Mode Comparator”
Impact of Harmonics on Power Quality and Losses in Power Distribution Systems
Published by M. Jawad Ghorbani, H. Mokhtari**, Dept. of CSEE, West Virginia University, Morgantown, WV, USA, ** Dept. of EE, Sharif University of Technology, Tehran, Iran. ABSTRACT – This paper investigates the harmonic distortion and losses in power distribution systems due to the dramatic increase of nonlinear loads. This paper tries to determine the amountContinue reading “Impact of Harmonics on Power Quality and Losses in Power Distribution Systems”
Comparison of Two Concepts for Modeling of Lightning Strike into Overhead Line
Published by Karol ANISEROWICZ, Politechnika Białostocka, Wydział ElektrycznyORCID: 0000-0001-8895-3954 Abstract. The paper presents a comparison of results of determining the lightning current flow in the shield wires of a high voltage line, using the model of lightning in the form of a lumped current generator and the antenna model, which takes the electromagnetic coupling intoContinue reading “Comparison of Two Concepts for Modeling of Lightning Strike into Overhead Line”
Impedance Correction Method of Distance Relay on High Voltage Transmission Line
Published by Samira SEGHIR, Tahar BOUTHIBA, Université des Sciences et de la Technologie d’Oran Mohamed BOUDIAF, USTO-MB, Faculté de Génie Electrique, Laboratoire LGEO, BP 1505 El M’Naouer, 31000 Oran, Alegria Abstract. A distance protection relay plays a major role in faults detection in the electric transmission line. The fault resistance has an effect on theContinue reading “Impedance Correction Method of Distance Relay on High Voltage Transmission Line”
Analysis of Thermal Field in 110 kV Cable Systems
Published by Janusz TYKOCKI1, Yong YUE2, Andrzej JORDAN3, The State College of Computer Science and Business Administration in Łomża (1), University of Bedfordshire (2), Visiting professor at University of Bedfordshire (UK), The State College of Computer Science and Business Administration in Łomża (3) Abstract. The paper presents the distribution of temperature field in high voltageContinue reading “Analysis of Thermal Field in 110 kV Cable Systems”