Published by Felix KALUNTA1, Tolulope AKINBULIRE2, Frank OKAFOR3, Federal Institute of Industrial Research, Lagos (1), University of Lagos (2,3) Abstract. A hybrid technique for the analysis of series resonance in power network with aggregate harmonic sources is hereby presented. It involves the identification of resonant modes using admittance scan and computation of network currents atContinue reading “Analysis of Series Resonance in Power Distribution Networks with Aggregate Harmonic Sources”
Tag Archives: Resonance
Practical Experiences and Mitigation Methods of Harmonics in Wind Power Plants
Published by Babak Badrzadeh, Senior Member, IEEE, and Manoj Gupta IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 49, NO. 5, SEPTEMBER/OCTOBER 2013 Abstract—This paper discusses practical experiences and mitigation methods of harmonics in wind power plants. Traces obtained from harmonic measurements of actual wind turbines are presented for the type 3 and type 4 turbines, andContinue reading “Practical Experiences and Mitigation Methods of Harmonics in Wind Power Plants”
Main Effects of Harmonics in Electrical Installations
Published by Electrical Installation Wiki, Chapter M. Power harmonics management – Main effects of harmonics in electrical installations Effects of harmonics – Resonance The simultaneous use of capacitive and inductive devices in distribution networks may result in parallel or series resonance. The origin of the resonance is the very high or very low impedance values atContinue reading “Main Effects of Harmonics in Electrical Installations”
Billing Measurements in the High and Extra-High Voltage Network taking into Account the New Frequency Classes According to IEC 61869-1 ED2 (AFDIS)
Published by Roland Buerger (Senseleq B.V.), Dr. Thomas Heid (CONDIS SA) Internationally, it is not easy to specify the range of high voltage exactly. The boundary between medium and high voltage is between 30 kV and 100 kV, depending on local and historical conditions. In the current version of EN 50160 from 2020, the voltageContinue reading “Billing Measurements in the High and Extra-High Voltage Network taking into Account the New Frequency Classes According to IEC 61869-1 ED2 (AFDIS)”
Industrial Harmonic Filter Design
Published by Electrotek Concepts, Inc., PQSoft Case Study: Industrial Harmonic Filter Design, Document ID: PQS0504, Date: June 30, 2005. Abstract: The industrial harmonic problem can be solved using a comprehensive approach including site surveys, harmonic measurements, and computer simulations. Simple calculations are used to determine the system resonant frequencies and then the preliminary model development isContinue reading “Industrial Harmonic Filter Design”
Reactors in a Power System
Published by Alex Roderick, EE Power – Technical Articles Reactors in a Power System, May 03, 2021. This article highlights two common types of reactors which are the dry-type and the oil-immersed. In an AC circuit, reactance is the opposition to current flow. A reactor, also known as a line reactor, is a coil wired in series betweenContinue reading “Reactors in a Power System”