Published by 1. S. Abdul Rahman, 2. Estifanos Dagnew Mitiku, 3. Shumye Birhan Mule, 4. Gebrie Teshome Aduye, 5. Mekete Asmare Huluka, 6. Solomon Mesfin Institute of Technology, University of Gondar, Ethiopia Abstract – Dynamic voltage restorer is considered to be one of the best device to compensate voltage sag and swell. Recently the DVRsContinue reading “Voltage Sag Mitigation Using Direct Converter Based DVR without Error Signal”
Tag Archives: MATLAB/Simulink
Analysis of Transient Waveforms in a Power System at Asymmetrical Short-Circuits
Published by Piotr PRUSKI, Stefan PASZEK, Silesian University of Technology Abstract. In the paper, there is presented the analysis of disturbance waveforms of a synchronous generator operating in a single-machine power system consisting of a generating unit connected by a high-voltage power line to a bus. There are considered disturbances in the form of symmetricalContinue reading “Analysis of Transient Waveforms in a Power System at Asymmetrical Short-Circuits”
Arc Plasma Energy Evolvement in 60 kV Network Circuit Breakers
Published by Salah Belkhir1, Abderrahmane Ziani1, Hakim Azizi2, Hocine Moulai1,University of Science and Technology Houari Boumediene, Algiers, Algeria (1), University Ziane Achour, Djelfa, Algeria (2) ORCID: 1. 0000-0002-5106-2821 Abstract. The evolvement of the electric and energetic properties of electric arcs at the poles opening of a circuit breaker (CB) is described by nonlinear mathematical models.Continue reading “Arc Plasma Energy Evolvement in 60 kV Network Circuit Breakers”
Comparison of the Results of Simulation Modeling of an Asynchronous Electric Motor with the Calculated Electrodynamic and Energy Characteristics
Published by 1. Oleg GUBAREVYCH1, 2. Svitlana GOLUBIEVA1, 3. Inna MELKONOVA2, State University of Infrastructure and Technologies (1), Volodymyr Dahl East Ukrainian National University (2)ORCID: 1. 0000-0001-7864-0831; 2. 0000-0001-8285-7566; 3. 0000-0001-6173-1470 Abstract. The paper presents the results of a comparison of the electrodynamic and energy characteristics and parameters of an asynchronous motor, obtained by simulationContinue reading “Comparison of the Results of Simulation Modeling of an Asynchronous Electric Motor with the Calculated Electrodynamic and Energy Characteristics”
PQ & DQ Based Shunt Active Power Filter with PWM & Hysteresis Techniques
Published by 1. Mahmood T. Alkhayyat1, 2. Mohammed Y. Suliman2, 3. Faisal Falah Aiwa3, Northern Technical University (1), (2), (3) IraqORCID: 1. 0000-0001-6119-7845, 2. 0000-0002-1250-6362, 3. 0000-0003-1974-6614 Abstract. Power quality is mainly affected by any deviation in voltage, current, or frequency that results in damage, upset, or failure of end-use equipment. Non-linear loads like powerContinue reading “PQ & DQ Based Shunt Active Power Filter with PWM & Hysteresis Techniques”
Modeling the Transient Response of Lightning Current on Grounding Systems Wind Turbines
Published by Amina DJABOREBBI, Boubakeur ZEGNINI, Djillali MAHI, Amar TELIDJI University of Laghouat, PoBox 37 G, Mkam Laghouat 03000, Algeria. Abstract. The paper deals with transient analysis of grounding systems wind turbines. To improve the accuracy of lightning impact studies on wind power grid generation, it is necessary to develop faster, more accurate simulation toolsContinue reading “Modeling the Transient Response of Lightning Current on Grounding Systems Wind Turbines”
Switching Strategies of Single Stage Battery based Microgrid
Published by Sudhakiran Ponnuru1, Ashok Kumar R1, Jothi Swaroopan NM2, Annamalai University (1), RMK Engineering College (2), India ORCID: 1. 0000-0002-5345-5709, 2. 0000-0001-6994-7591, 3. 0000-0001-7671-5190 Abstract. Renewable sources creates new opportunity when it is integrated with the microgrid increasing the energy efficiency of the system. This paper focuses on the adaptive control strategies which utilizesContinue reading “Switching Strategies of Single Stage Battery based Microgrid”
Differential Relay Protection for Prototype Transformer
Published by Bashar M. SALIH, Mohammed A. IBRAHIM, Ali N. HAMOODI, Northern Technical University Abstract. This paper represents the differential protection relay that used to protect the prototype-Terco power transformer. Matlab/Simulink is used to simulate the protection system. The power differential protection algorithm has been simulated and tested on a 2KVA power transformer under differentContinue reading “Differential Relay Protection for Prototype Transformer”
Accurate Fault Detection and Location in Power Transmission Line Using Concurrent Neuro Fuzzy Technique
Published by Patrick S. Pouabe Eboule, & Ali N. Hasan, University of Johannesburg, South Africa Abstract. In this paper a new approach for the detecting and locating different kinds of faults on power transmission lines using the concurrent neurofuzzy technique (CNF) is introduced. This approach relies on the advantages of combining fuzzy logic (FL) andContinue reading “Accurate Fault Detection and Location in Power Transmission Line Using Concurrent Neuro Fuzzy Technique”
Impact of Electric Vehicle Charging Station on Power Quality
Published by M. S. Arjun1, N. Mohan1, K. R. Sathish2, Arunkumar Patil3, G. Thanmayi4.1Department of Electrical and Electronics Engineering, JSS Science and Technology University, Mysore, India2Department of Electrical and Electronics Engineering, ATME College of Engineering, Mysore, India3Department of Electrical Engineering, Central University of Karnataka, Kalaburagi (Gulbarga), India4M. Tech-Energy System and Management, Department of Electrical andContinue reading “Impact of Electric Vehicle Charging Station on Power Quality”