Using the Method of the Spectral Analysis in Diagnostics of Electrical Process of Propulsion Systems Power Supply in Electric Car

Published by Yuriy BORODENKO1, Leonids RIBICKIS2, Anatolijs ZABASTA3, Shchasiana ARHUN4, Nadezhda KUNICINA5, Anastasia ZHIRAVETSKA6, Hanna HNATOVA7, Andrii HNATOV8, Antons PATLINS9, Konstantins KUNICINS10, Kharkiv National Automobile and Highway University (1), Riga Technical University (2), Riga Technical University (3), Kharkiv National Automobile and Highway University (4), Riga Technical University (5), Riga Technical University (6), Kharkiv National AutomobileContinue reading “Using the Method of the Spectral Analysis in Diagnostics of Electrical Process of Propulsion Systems Power Supply in Electric Car”

Management System for Electric Vehicle Battery Pack

Published by Andrzej ŁEBKOWSKI, Gdynia Maritime University, Department of Ship Automation Abstract. Electric vehicles (EVs) emerged as a next step in the evolution of transport technology. The article describes structure of system used for optimal management and monitoring of electric vehicle parameters, especially in regions of low possible ambient temperature. System can be used inContinue reading “Management System for Electric Vehicle Battery Pack”

Introduction to Off-Grid and Hybrid EV Charging System Architectures

Published by Rakesh Kumar, EE Power – Technical Articles: Introduction to Off-Grid and Hybrid EV Charging System Architectures, December 05, 2022. Off-grid and Hybrid Charging Systems are important components of the electric vehicle ecosystem. Learn more about these architectures in this technical article. Electric Vehicle Charging Stations (EVCS) are the topic of the hour to caterContinue reading “Introduction to Off-Grid and Hybrid EV Charging System Architectures”

Implementing Electric Vehicles in Public Services: A Case Study Research

Published by João Reis, Department of Economics, Management, Industrial Engineering and Tourism, GOVCOPP, Aveiro University, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal. Email: reis.joao@ua.pt Abstract: In the last years, most European countries have developed strategies to implement the use of electric vehicles. This paper uses a qualitative case study research in the automotive industry toContinue reading “Implementing Electric Vehicles in Public Services: A Case Study Research”

Electric Vehicles: A Data Science Perspective Review

Published by Dario Pevec *,† , Jurica Babic † and Vedran Podobnik †, Faculty of Electrical Engineering and Computing, University of Zagreb, Zagreb 10000, Croatia;jurica.babic@fer.hr (J.B.); vedran.podobnik@fer.hr (V.P.)* Correspondence: dario.pevec@fer.hr† These authors contributed equally to this work. Abstract: Current trends are showing that the popularity of electric vehicles (EVs) has significantly increased over the lastContinue reading “Electric Vehicles: A Data Science Perspective Review”

A Case Study on Wired and Wireless Charger Standards in India for Electric Vehicle Application

Published by Shivanand M N1, Y. Maruthi1 Phaneendra Babu Bobba2, Sandeep Vuddanti11GRIET, EEE Department, Hyderabad, Telangana, India2CUK, Electrical Engineering Department, Kalburgi, Karnataka, India*Corresponding author: shivanandnaduvin@gmail.com Abstract. India has taken major step in adopting the electric vehicle by means of FAME Scheme (Fast Adoption and Manufacturing of Electric Vehicles), a government initiative. ARAI (Automotive Research AuthorityContinue reading “A Case Study on Wired and Wireless Charger Standards in India for Electric Vehicle Application”

Investigating Electric Vehicle (EV) Charging Station Locations for Agartala, India

Published by Somudeep Bhattacharjee1, Saima Batool2, Champa Nandi1 and Udsanee Pakdeetrakulwong3,* , 1Tripura University, 2School of Information Systems, Curtin Business School, Curtin University, 3Nakhon Pathom Rajabhat University*Corresponding author; e-mail: udsanee@webmail.npru.ac.th Abstract. Selecting the location for installing electric vehicles charging stations is important to ensure EV adoption and also to address some of the inherent risksContinue reading “Investigating Electric Vehicle (EV) Charging Station Locations for Agartala, India”

Developing Infrastructure to Charge Electric Vehicles

Published by U.S. Department of Energy – Energy Efficiency and Renewable Energy Alternative Fuels Data Center Consumers and fleets considering electric vehicles (EVs)—which include all-electric vehicles and plug-in hybrid electric vehicles (PHEVs)—need access to charging stations. For most drivers, this starts with charging at home or at fleet facilities. Charging stations at workplaces and public destinations may help bolster market acceptanceContinue reading “Developing Infrastructure to Charge Electric Vehicles”

Insulation Failure Detection in EV Batteries

Published by Ryan Hsu, Bright Toward Industrial Co., Ltd., EE Power – Industry Article: Insulation Failure Detection in EV Batteries, May 15, 2023. One of the issues with electric vehicle batteries is insulation failure. A proven approach to detecting and correcting this failure lies in ground-fault detection. However, as higher voltages become increasingly common in electricContinue reading “Insulation Failure Detection in EV Batteries”

Making Sense of Electric Vehicle Charging Options

Published by Mike Falter, EE Power – Market Insights: Making Sense of Electric Vehicle Charging Options, September 07, 2022. When it comes to charging your electric vehicle there are several options to consider based on speed, convenience and cost. In the recent article on the Wallbox acquisition of COIL, EE Power briefly reviewed the Wallbox portfolio of EV chargingContinue reading “Making Sense of Electric Vehicle Charging Options”