Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Substation Harmonic Measurement Data Evaluation, Document ID: PQS1016, Date: October 15, 2010. Abstract: This case study presents a distribution harmonic data analysis for a substation monitoring location for a three-month period. The utility substation included a step-down transformer and a number of distribution feeders that supplied aContinue reading “Distribution Substation Harmonic Measurement Data Evaluation”
Category Archives: Case Studies
Analysis of Lightning Current Distribution in the Lightning Protection System (LPS) with using Numerical Simulations
Published by Konrad SOBOLEWSKI, Warsaw University of Technology Abstract. The paper describes the numerical model of a typical lightning protection system (LPS). This model was used to get information’s about lightning current distributions as an effect of direct lightning strike to this protection system. To perform this task was chosen software MATLAB/SIMULINK. With this toolContinue reading “Analysis of Lightning Current Distribution in the Lightning Protection System (LPS) with using Numerical Simulations”
Industrial Grids with Frequency Inverters and Localization of the Earth Fault
Published by Tomáš SNIEGOŇ, Jiří GURECKY, Department of Electrical Power Engineering, VŠB – TU Ostrava Abstract. This article focuses on industrial grids with frequency inverters and evaluation of the earth fault and its localization. In the first part the system of localization of the earth fault, industrial grids with frequency inverters and typical application inContinue reading “Industrial Grids with Frequency Inverters and Localization of the Earth Fault”
Research of the Fault Location Method of Distribution Network
Published by Yan LI1, Yu GUO2, Xiping WANG1,Electrical engineering department Hebei Engineering and Technical College (1), Langfang Yongqing supply Co.,Ltd. (2) Abstract. The rough set theory is used to realize the automatic fault location method of the rural power distribution network. The decision table of the distribution network fault location is based on the faultContinue reading “Research of the Fault Location Method of Distribution Network”
Apply to the Township’s Small Substation
Published by Shoucheng DING1,2, Limei XIAO1,2, Rui HUANG1, Jie LIU1, Shizhou YANG1, Xiao CHAI1,College of Electrical and Information Engineering, Lanzhou University of Technology (1), Key Laboratory of Gansu Advanced Control for Industrial Processes (2) Abstract. This paper designed a small terminal of a 35kV substation; it can meet the substation area electricity and the futureContinue reading “Apply to the Township’s Small Substation”
Distribution Substation Capacitor Bank Evaluation
Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Substation Capacitor Bank Evaluation, Document ID: PQS1014, Date: October 15, 2010. Abstract: This case study presents a utility distribution substation capacitor bank harmonic analysis. The simulations were completed using the SuperHarm program. The investigation included frequency response and harmonic distortion simulations for a utility substation that includedContinue reading “Distribution Substation Capacitor Bank Evaluation”
Distribution Feeder Resonance and Harmonic Filter Evaluation
Published by Electrotek Concepts, Inc., PQSoft Case Study: Distribution Feeder Resonance and Harmonic Filter Evaluation, Document ID: PQS1006, Date: March 15, 2010. Abstract: Utility power system harmonic problems can often be solved using a comprehensive approach including site surveys, harmonic measurements, and computer simulations. This case study presents the results for a utility distribution feeder resonanceContinue reading “Distribution Feeder Resonance and Harmonic Filter Evaluation”
The System for Testing the Resistance to the Surface Discharge and Erosion of the Polymeric Insulators
Published by Tomasz SAMBORSKI, Andrzej ZBROWSKI, Stanisław KOZIOŁ, Instytut Technologii Eksploatacji – Państwowy Instytut Badawczy Abstract. The introduced device allows performance of the research in the rotary testing of the resistance to the surface discharge and erosion of the polymeric insulators according to PN-EN 62217:2007. The applied control system of the operation of the deviceContinue reading “The System for Testing the Resistance to the Surface Discharge and Erosion of the Polymeric Insulators”
Evaluation of Harmonic Impacts from Compact Fluorescent Lights On Distribution Systems
Published by Electrotek Concepts, Inc., PQSoft Case Study: Evaluation of Harmonic Impacts from Compact Fluorescent Lights On Distribution Systems, Document ID: PQS0322, Date: April 16, 2003. Abstract: This case study presents the results of a research investigation into the impact of compact fluorescent lights (CFLs) on an existing distribution system. The analysis uses a combination ofContinue reading “Evaluation of Harmonic Impacts from Compact Fluorescent Lights On Distribution Systems”
Research on Design and Control of Microgrid System
Published by Yanbo CHE, Jian CHEN,School of Electrical Engineering & Automation, Tianjin University, Tianjin China. Abstract. Microgrid system has received more and more attention internationally in recent years. As the most effective form of distributed generations, microgrid system has also found wide applications in many areas. In this paper, the optimal configuration issue of microgridContinue reading “Research on Design and Control of Microgrid System”