Published by Information Technology Industry Council (ITI), 1250 Eye Street NW Suite 200, Washington DC 20005, 202-737-8888, http://www.itic.org The ITI (CBEMA) Curve, included within this Application Note, is published by Technical Committee 3 (TC3) of the Information Technology Industry Council (ITI, formerly known as the Computer & Business Equipment Manufacturers Association). It is available atContinue reading “ITI (CBEMA) Curve Application Note”
Category Archives: App Notes / White Papers
Paralleling Dissimilar Generators: Part 2 – Compatible Alternators
Published by By Gary Olson, Director of Technical Support, Cummins Power Generation, Power topic #9016 | Technical information from Cummins Power Generation – White Paper Paralleled alternators are compatible if they can operate in parallel without having damaging or disruptive neutral currents flowing between them. The magnitude of neutral current flow related to the dissimilarityContinue reading “Paralleling Dissimilar Generators: Part 2 – Compatible Alternators”
Technical Paper: Semiconductor Equipment Voltage Sag Immunity Improvements
This Technical Paper Written by: Mark Stephens, P.E. Engineering Manager, EPRI PEAC Corporation, Semiconductor & Industrial PQ Group, EPRI PEAC Corporation, 942 Corridor Park Boulevard Knoxville, Tennessee 37932, Phone: (865)-218-8022, Fax: (865)-218-8001 mstephens@epri-peac.com, http://www.f47testing.com, June 13th, 2002 Introduction The end of the report read…“…Imagine a time in the not so distant future when the industryContinue reading “Technical Paper: Semiconductor Equipment Voltage Sag Immunity Improvements”
K-Factor Defined
Published by Xitron Technologies, Manufacturers of Engineering and Production Test Equipment, An ISO 9001:2000 registered company, AN102 Application Note. In today’s industrial workplace, the proliferation of solid state devices (lighting ballasts, motor drives and controls, communications equipment, and other DC-powered loads) has created a major problem for specifying engineers, contractors and building owners. The non-linearContinue reading “K-Factor Defined”
Variable Frequency Drive (VFD) Testing Applications
Published by Dranetz Technologies, Inc. VFD motor controls have become very popular for both retrofits and in new applications. They offer increased energy efficiency, potential for less motor wear, lower startup currents and more. Potential disadvantageous include producing harmonics and damaged motors if they are not controlled properly. VFD’s use a Pulse Width Modulated (PWM) voltageContinue reading “Variable Frequency Drive (VFD) Testing Applications”
Dranetz HDPQ Family Generator & Mission Critical Testing
Published by Dranetz Technologies, Inc. INTRODUCTION Data centers, hospitals, mission critical and other facilities rely on standby power. This is often generators that are ready to carry the load if there is an interruption in the primary power source. Such facilities often have UPS systems for a seamless transition to standby power, and to carry theContinue reading “Dranetz HDPQ Family Generator & Mission Critical Testing”
Strategies for Investigating Flicker
Published by Wayne LaFleur, Senior Engineer, Power Monitors, Inc. Email: wlafleur@powermonitors.com, Website: powermonitors.com, (800) 296-4120, February 2014. White Paper. ABSTRACT Investigating f licker issues with PMI recorders can be straightforward if the right data is collected, and analyzed with ProVision. By enabling and examining Pst and IFL flicker data, in addition to RMS voltage andContinue reading “Strategies for Investigating Flicker”
Energy Platform EP1 Trend Data Time Interval
Published by Terry Chandler, Director of Engineering, Power Quality (Thailand) Co., Ltd. Emails: terryc@powerquality.co.th,TChandler@Dranetz.com The EP1 is Energy Platform has a slightly different time interval for the trended data from the other Dranetz portable products. The PX/PG/PV have a minimum intervals of 1 second, 10 seconds and 1 minute. Note: There are some limitations onContinue reading “Energy Platform EP1 Trend Data Time Interval”
Passive Harmonic Filter Design
Published by Kerim Ozer, Senior Electrical Engineer, Enspec Power Ltd. Email: kerim.ozer@enspecpower.com A technical review of how passive harmonic filter types have an impact on network impedance profiles in terms of damping. A review of a harmonic filter design study was carried out for an industrial Plant, which included a total capacity of >100MW smelters,Continue reading “Passive Harmonic Filter Design”
Key Changes and Differences between the New IEEE 519- 2014 Standard and IEEE 519-1992
Written by Ian Wallace, Chief Engineer, Power Quality Solutions, TCI® Technical Paper. Introduction IEEE Std 519-2014 is a newly published revision to the IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems. It supersedes the IEEE Std 519-1992 revision. The overarching goal of the 2014 revision is the same as the 1992Continue reading “Key Changes and Differences between the New IEEE 519- 2014 Standard and IEEE 519-1992”