Earth Fault Protection Supported with Adaptive Admittance Criteria

Published by Józef LORENC, Krzysztof ŁOWCZOWSKI, Bogdan STASZAKPolitechnika Poznańska, Instytut Elektroenergetyki Abstract. In this paper possibilities for improvement of earth fault protection by adjustment of protective relay settings due to change of neutral point impedance in medium voltage networks are presented. Streszczenie. W artykule przedstawiono zagadnienia dotyczące możliwości poprawy skuteczności działania zabezpieczeń ziemnozwarciowych typu YY0Continue reading “Earth Fault Protection Supported with Adaptive Admittance Criteria”

Insulation Failure Detection in EV Batteries

Published by Ryan Hsu, Bright Toward Industrial Co., Ltd., EE Power – Industry Article: Insulation Failure Detection in EV Batteries, May 15, 2023. One of the issues with electric vehicle batteries is insulation failure. A proven approach to detecting and correcting this failure lies in ground-fault detection. However, as higher voltages become increasingly common in electricContinue reading “Insulation Failure Detection in EV Batteries”

Wind Farm and System Modelling Evaluation in Harmonic Propagation Studies

Published by G. A. Mendonça1, H. A. Pereira1,2 and S. R. Silva1,1 Graduate Program in Electrical Engineering – Universidade Federal de Minas Gerais Av. Antônio Carlos 6627, 31270-901, Belo Horizonte, MG, Brazil. Phone: +55-31-3409-4842, e-mail: gforti@gmail.com, heverton.pereira@ufv.com.br, selenios@dee.ufmg.br2 Department of Electrical Engineering, Universidade Federal de Viçosa Av. P.H.Rolfs S/N,36570-000, Viçosa, MG, Brazil Abstract. Wind powerContinue reading “Wind Farm and System Modelling Evaluation in Harmonic Propagation Studies”

Analysis of the Impact of Secondary Winding Impedance on the Parameters of Transformer Type Superconducting Current Limiters

Published by Joanna KOZIEŁ, Lublin University of Technology, Institute of Electrical Engineering and Electrotechnologies Abstract. The paper presents the classification of superconducting fault current limiters. In particular the principle of construction and operations of superconducting current limiter of transformer type is presented. Functional physical model of such a limiter, designed, manufactured in the Laboratory ofContinue reading “Analysis of the Impact of Secondary Winding Impedance on the Parameters of Transformer Type Superconducting Current Limiters”

Making Sense of Electric Vehicle Charging Options

Published by Mike Falter, EE Power – Market Insights: Making Sense of Electric Vehicle Charging Options, September 07, 2022. When it comes to charging your electric vehicle there are several options to consider based on speed, convenience and cost. In the recent article on the Wallbox acquisition of COIL, EE Power briefly reviewed the Wallbox portfolio of EV chargingContinue reading “Making Sense of Electric Vehicle Charging Options”

Computer Assisted Harmonics Analysis

Published by Prof. Silviu Darie, PhD (EE), Technical University Cluj Napoca, Romania, Honorary Member of the Romanian Technical Sciences Academy. Email: silviu.darie@enm.utcluj.ro. Abstract: Based on the author’s experience one describes in field tested methodologies which can be employed in solving the frequency-based power quality problems. A generic approach is presented and an experience-based assessment isContinue reading “Computer Assisted Harmonics Analysis”

Single Line to Ground-Fault Detection for Unit Generator-Transformer based on Wavelet Transform and Neutral Networks

Published by Ahmad Rizal SULTAN1, Mohd Wazir bin MUSTAFA2, Makmur SAINI3, Ahmad GAFFAR41,3,4 Politeknik Negeri Ujung Pandang, South Sulawesi-Indonesia2Universiti Teknologi Malaysia, Faculty of Electrical Engineering, Johor-Malaysia Abstract. The aim of this paper is to detect the single line to ground fault on the unit generator- transformer. A new ground fault detection scheme based on theContinue reading “Single Line to Ground-Fault Detection for Unit Generator-Transformer based on Wavelet Transform and Neutral Networks”

Charging Infrastructure and Testing of the Electric Vehicle Energy Battery Decline

Published by Anna ZIELIŃSKA, AGH University of Science and Technology Abstract: The article presents the infrastructure for charging electric vehicles, their development and the types and methods of charging. The paper presents the results of testing the level of vehicle charge depending on the route traveled and its dynamics. The test results show the changeContinue reading “Charging Infrastructure and Testing of the Electric Vehicle Energy Battery Decline”

Solar Power Plant with Distributed System of PV Panels

Published by Mariusz ŚWIDERSKI, Michał GWÓŹDŹ, Poznan University of Technolog Abstract. In the work the other approach to a photovoltaic system is presented. With regard to an improvement of reliability of a solar system, maintaining and improving system’s efficiency, authors proposed conception of the distributed PV system. This system consists of a set of individualContinue reading “Solar Power Plant with Distributed System of PV Panels”

Trends in Electric Vehicle Fast Charging

Published by Rakesh Kumar, EE Power – Technical Articles: Trends in Electric Vehicle Fast Charging, February 02, 2023. Ultra-fast charging methodology, ultra-fast charging station architectures, and improved battery technology are some promising trends for fast-charging electric vehicles. EVs hold the potential for decarbonizing the transportation sector. But the crucial impediment to the adoption of electrified transportationContinue reading “Trends in Electric Vehicle Fast Charging”