Grounding and Bonding — New Questions and Answers

Published by Ark Tsisserev, International Association of Electrical Inspectors (IAEI) Magazine, Canadian Perspectives – Grounding and Bonding — New Questions and Answers, July 1, 2021 Although Section 10 of the Canadian Electrical Code, Part I (CE Code), which applies to grounding and bonding, has been re-written in the 2018 edition of the Code, I keep receivingContinue reading “Grounding and Bonding — New Questions and Answers”

Design of the Electrical Installation Protection System

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Design of the electrical installation protection system To protect an electrical installation in a building, simple rules apply for the choice of • SPD(s);• its protection system. For a power distribution system, the main characteristics used to define the lightning protection system and select a SPDContinue reading “Design of the Electrical Installation Protection System”

Principle of lightning Protection

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Principle of lightning protection General rules of lightning protection Procedure to prevent risks of lightning strike The system for protecting a building against the effects of lightning must include: • protection of structures against direct lightning strokes;• protection of electrical installations against direct and indirect lightningContinue reading “Principle of lightning Protection”

Electrical Shock and its Effects

Published by Alex Roderick, EE Power – Technical Articles: Electrical Shock and its Effects, August 17, 2021. Anyone working on electrical equipment should have respect for all voltages, have knowledge of the principles of electricity, and follow safe work procedures. An electrical shock occurs when a body becomes a part of an electrical circuit. The effectsContinue reading “Electrical Shock and its Effects”

Overvoltage of Atmospheric Origin

Published by Electrical Installation Wiki, Chapter J. Overvoltage protection – Overvoltage of atmospheric origin Overvoltage definitions Overvoltage (in a system) any voltage between one phase conductor and earth or between phase conductors having a peak value exceeding the corresponding peak of the highest voltage for equipment. Definition from the International Electrotechnical Vocabulary (IEV 604-03-09); available on [1] VariousContinue reading “Overvoltage of Atmospheric Origin”

The Basics of Grounding Electrical Systems

Published by Lorenzo Mari, EE Power – Technical Articles: The Basics of Grounding Electrical Systems, April 10, 2020. This article breaks down the complexities found in the fundamental field of grounding for the correct, faultless operation of electrical systems. Grounding, or earthing, is a fundamental topic for the correct operation of electrical systems and devices. However,Continue reading “The Basics of Grounding Electrical Systems”

Stator Earth Fault in 200MW Generator – A Case Study

Published by Mr. V.Veerapandi, Sr.Manager(ser)/SAS, Email:vpandi@bhelpswr.co.in Introduction One of 200 MW old machine was experienced stator earth fault and the unit was tripped when the load was around 154 MW. The stator earth fault was attended on emergency basis and the unit was brought back with minimum possible time. This article covers observations, analysis ofContinue reading “Stator Earth Fault in 200MW Generator – A Case Study”

AC Equipment Grounding: Creating a Safe Fault Current Path to Ground

Published by Lorenzo Mari, EE Power – Technical Articles: AC Equipment Grounding: Creating a Safe Fault Current Path to Ground, August 07, 2020. Learn about the merits of the equipment grounding to protect people in faulted AC power systems. Electrical equipment casings should be at earth potential under normal conditions. When a fault occurs in anContinue reading “AC Equipment Grounding: Creating a Safe Fault Current Path to Ground”

How to Improve Resistance to Ground

Published by Lorenzo Mari, EE Power – Technical Articles: How to Improve Resistance to Ground, September 25, 2020. Learn about the methods used to lower the resistance of a grounding electrode When the soil resistivity is high, and the resistance to ground exceeds the required values, specific techniques are useful to decrease it. This article evaluatesContinue reading “How to Improve Resistance to Ground”

System and Equipment Grounding Safety

Published by Alex Roderick, EE Power – Technical Articles: System and Equipment Grounding Safety, August 15, 2021. Grounding is used to provide a safe path for a fault current to flow. Grounding is an integral part of any properly operating electrical system. In residence, grounding protects the occupants by providing a safe pathway for unwanted electricityContinue reading “System and Equipment Grounding Safety”