Published by U.S. Department of Energy Office of Energy Efficiency & Renewable Energy, Article: Building Technologies Program SOLID-STATE LIGHTING TECHNOLOGY FACT SHEET, Website: ssl.energy.gov Lifetime and Reliability Long life has been billed as a key advantage of LEDs, but understanding and communicating how LED products fail and how long they last can be challenging. WhileContinue reading “Lifetime and Reliability”
Category Archives: Uncategorized
Happy Holidays & a Happy New Year 2022!
“Life is like riding a bicycle. To keep your balance you must keep moving.” ~ Albert Einstein
A Case Study on EMI Noise adversely affecting the performance & reliability of Robotics & Automation
Published by J A Simon, Chief Executive, Waveforms, Email: waveformspower@gmail.com, Website: http://www.waveforms.co.in Automation improves productivity but it can also derail the automation process due to the issue of harmonics & Emi (high-frequency noise). This case study is about how to improve the reliability, electrical efficiency, & power quality of robotics & automation. This real-time caseContinue reading “A Case Study on EMI Noise adversely affecting the performance & reliability of Robotics & Automation”
Low Voltage Distribution Board Safety
March, 2007 Published by Terry Chandler Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th Accidental Death is REAL!! Electrical Shock Fatalities in the USA Electric shocks are responsible for about 1,000 deaths in the United States each year, or about 1% of all accidental deaths. Electric shocks cause death in 3-15% of cases.Continue reading “Low Voltage Distribution Board Safety”
The Evolution of Revenue Meters to Smart Meters
with Terence (Terry) E. Chandler, Founder and Director of Engineering, Power Quality Inc. Tuesday, March 2nd at 11:00 am – 12:00 pm (EST) Join us on Tuesday, March 2nd at 11 am (EST) as we welcome industry expert and Powermetrix distributor Terry Chandler from Power Quality Inc. to discuss the evolution of revenue meters to smart meters. Terry has moreContinue reading “The Evolution of Revenue Meters to Smart Meters”
Power Quality (Thailand) Co., Ltd. Instrument Rental by Dranetz
February 15th, 2021 Portable Power Quality Meters HDPQ Xplorer / Power Xplorer with Accessories Per Week: THB 18,000 Per Month: THB 64,800 HDPQ Guide / Power Guide with Accessories Per Week: THB 16,000 Per Month: THB 57,600 HDPQ Visa / Power Visa with Accessories Per Week: THB 14,000 Per Month: THB 50,400 Energy Platform EP1Continue reading “Power Quality (Thailand) Co., Ltd. Instrument Rental by Dranetz”
EPRI: Efficient Electrification
Newsletter: February 2021
EPRI PQ Knowledge Development and Transfer 2020 Year-End Update
January 2021 The EPRI Power Quality Knowledge Development and Transfer supplemental project provides a wealth of high-impact resources in a well-designed, readable, and accessible format. Paramount among these are numerous and highly readable documents covering a wide range of PQ topics, written not only for use by busy PQ professionals, but also to expedite problemContinue reading “EPRI PQ Knowledge Development and Transfer 2020 Year-End Update”