Published by Arindam Ghosh, Curtin University, Perth, DLP Thailand, Sept. 2018.
Category Archives: Power Quality
Power Quality Issues at Utilities Serving Rural Areas and Smaller Towns
Published by Dr. Sioe T. Mak, Power Quality Specialist and Steven E. Spencer , President – CEO, ADVANTAGE ENGINEERING, Inc. 769 Spirit of St. Louis Blvd., Chesterfield, MO. 63005, USA, Tel. 314-530-0470, Fax. 314-530-0670, E-mail ae@inlink.com ABSTRACT Many small and medium size industries and very large farming operations move into rural areas and small townsContinue reading “Power Quality Issues at Utilities Serving Rural Areas and Smaller Towns”
Nonlinear Loads Effect on Harmonic Distortion and Losses of Distribution Networks
Published by Mohammad Jawad Ghorbani, Salar Atashpar, Arash Mehrafrooz, Iran Energy Efficiency Organization (IEEO), Tehran, Iran. Emails: mjghorbany@ee.sharif.edu, s_atashpar@yahoo.com, arashmehrafrooz@saba.org.ir, Hossein Mokhtari, Sharif University of Tech, Tehran, Iran. Email: Mokhtari@sharif.edu Published in 26th International Power System Conference, Oct 31st – Nov 2nd, 2011, Tehran, Iran. Keywords-component; Harmonic Distortion, Loss estimation, Non-linear loads, Norton equivalent model,Continue reading “Nonlinear Loads Effect on Harmonic Distortion and Losses of Distribution Networks”
Why Specifying IEC 61000-4-30 Class A Is Not Enough
Published By Terry Chandler Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th 1. A new revision of the IEC standard for PQ monitors 61000-4-30 Class Edition 3 2015 has been released. Why? It includes new parameters and new requirements for accuracy over the entire operating temperature range. 2. The PQ Instrument must haveContinue reading “Why Specifying IEC 61000-4-30 Class A Is Not Enough”
Laboratory Investigation of the Input Current Characteristics of Modern Domestic Appliances for Varying Supply Voltage Conditions
Published by Sean Elphick, Senior Member, IEEE University of Wollongong, elpho@uow.edu.auPhilip Ciufo, Senior Member, IEEE University of Wollongong, ciufo@uow.edu.auSarath Perera, Member, IEEE, University of Wollongong, sarath@uow.edu.au Publication Details S. Elphick, P. Ciufo & S. Perera, “Laboratory investigation of the input current characteristics of modern domestic appliances for varying supply voltage conditions,” in 14th International ConferenceContinue reading “Laboratory Investigation of the Input Current Characteristics of Modern Domestic Appliances for Varying Supply Voltage Conditions”
Phasor-Based Approach for Harmonic Assessment from Multiple Distributed Energy Resources
Published by Reza Arghandeh & Alexandra von Meier, Member IEEE, CIEE, EECS Dept, University of California, Berkeley, Berkeley, CA, USA. Email: arghandeh@berkeley.ed Robert Broadwater, Senior Member IEEE, ECE Dept Virginia Tech, Blacksburg, VA, USA Abstract — This paper analyzes impacts and interactions of harmonics from multiple sources, especially distributed energy resources, on distribution networks. WeContinue reading “Phasor-Based Approach for Harmonic Assessment from Multiple Distributed Energy Resources”
Power Quality Standards
Published by Mark McGranaghan, Electrotek Concepts, Inc. Electrical Contractor Magazine, Power Quality for the Electrical Contractor Course Introduction Power quality has always been important. However, for many years the equation defining power quality was very simple: POWER QUALITY = RELIABILITY Customer loads were linear in nature. When a sinusoidal voltage was supplied to them, theyContinue reading “Power Quality Standards”
Application of IEEE STD 519-1992 Harmonic Limits
Published by Thomas M. Blooming, P.E., Email: t.blooming@ieee.org, Eaton Electrical Asheville, North Carolina Daniel J. Carnovale, P.E., Email: DanielJCarnovale@eaton.com, Eaton Electrical Pittsburgh, Pennsylvania Presented at the 2005 IEEE IAS Pulp and Paper Industry Conference in Appleton, WI. Abstract IEEE Std 519-1992 is a useful document for understanding harmonics and applying harmonic limits in power systems.Continue reading “Application of IEEE STD 519-1992 Harmonic Limits”
Energy Monitoring & Usage Evaluation
Published By Terry Chandler Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. Emails: terryc@powerquality.org, terryc@powerquality.co.th
Electrical Overstress – Many Sources; Any Solutions?
Published by Terry Welsher, Dangelmayer Associates, ESD Association, Industry Council on ESD Targets. Website: http://www.dangelmayer.com