Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems

Published by Paweł PIJARSKI, Sylwester ADAMEK, Robert JĘDRYCHOWSKI, Klara SEREJA, Lublin University of Technology, Department of Electrical Networks and Security Abstract. An increasing number of connected prosumer installations, mainly photovoltaic ones, can cause problems with the operation of lowvoltage networks such as voltage fluctuations. These problems can be solved by an adequate control of theContinue reading “Monitoring the Impact of Prosumer Micro Installations on the Electrical Parameters of Low-Voltage Network Systems”

Control System for Distributed Generation in Low Voltage Network Systems

Published by Robert JĘDRYCHOWSKI, Klara SEREJA, Politechnika Lubelska, Katedra Sieci Elektrycznych i Zabezpieczeń, Poland Abstract. Implementation of prosumer energy generation to low-voltage network systems involves both benefits and technological problems concerning the grid operation. Electricity generation in LV network systems is of a distributed and quite unpredictable character. In those systems, solar PV installations, whoseContinue reading “Control System for Distributed Generation in Low Voltage Network Systems”

Advantages of Interwinding Capacitive Test Setup in FRA Diagnostics of Transformer Windings

Published by Wojciech SZOKA, Szymon BANASZAK, Konstanty M. GAWRYLCZYKZachodniopomorski Uniwersytet Technologiczny w Szczecinie, Katedra Elektrotechnologii i Diagnostyki, Poland Abstract. Transformers are the main element of the power system. Their reliable operation affects the efficiency of energy supply. Each transformer should be subjected to periodic diagnostic tests. Frequency response analysis (FRA) is a non-destructive diagnostic methodContinue reading “Advantages of Interwinding Capacitive Test Setup in FRA Diagnostics of Transformer Windings”

Distance Protection Analysis Applied for Distribution System with Distributed Generation

Published by João T. L. S. CAMPOS1,2, Huilman S. SANCA1, Flavio B. COSTA3, Benemar A. de SOUZA1, Universidade Federal de Campina Grande (1), Universidade Potiguar (2), Universidade Federal do Rio Grande do Norte (3) Abstract. In power systems, the over-current protection scheme and, optionally with directional function, and distance function are the main protection used,Continue reading “Distance Protection Analysis Applied for Distribution System with Distributed Generation”

Autotransformers for Power Systems

Published by Waldemar ZIOMEK, PTI Manitoba Inc., Winnipeg, MB, Canada Abstract. When the primary and secondary voltages are obtained from the same winding, or from two windings which are galvanically connected, such a transformer is called an autotransformer. The paper will focus on fundamentals, design and applications of autotransformers of core-type design. The selected problemsContinue reading “Autotransformers for Power Systems”

Capabilities of Polish Power Plants – Advantages and Threats

Published by Paweł SZMITKOWSKI1, Sylwia ZAKRZEWSKA1, Agnieszka GIL2, Paweł ŚWIDERSKI1Siedlce University, Social Science and Security Institute (1), Siedlce University, Institute of Mathematics and Physics (2) Abstract. The Polish energy infrastructure is very diverse, both in terms of the distribution of power plants in particular regions of the country, as well as the fuels used inContinue reading “Capabilities of Polish Power Plants – Advantages and Threats”

An Experimental Study of Wind Data of a Wind Farm in Kosovo

Published by Sabrije OSMANAJ1, Bukurie HOXHA2, Rexhep SELIMAJ2*1Faculty of Electrical and Computer Engineering, , 2Faculty of Mechanical Engineering, University of Pristina, Republic of Kosovo Abstract. In Kosovo, 97% of energy is generated from lignite-fired power plants. Apart from the energy generation, the combustion process emits around 8000 ktCO2/yr and 1.5 Mt of ash in theContinue reading “An Experimental Study of Wind Data of a Wind Farm in Kosovo”

Application of Additional Grounded Wires in High Voltage Overhead Power Lines to Reduce the Intensity of Electric Field Generated by Phase Wires

Pubsliehd by Jacek GUMIELA1, Dariusz SZTAFROWSKI1 Politechnika Wrocławska, Katedra Energoelektryki (1) Abstract. To minimize interference with the environment it is important to make every effort already at the design stage to spare the trouble associated with additional investment later on. Due to the value of land in urban areas, it is beneficial to take necessaryContinue reading “Application of Additional Grounded Wires in High Voltage Overhead Power Lines to Reduce the Intensity of Electric Field Generated by Phase Wires”

The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid

Published by Michał KONARSKI, Paweł WĘGIEREK, Lublin University of Technology, Faculty of Electrical Engineering and Computer Science, Lublin, Poland Abstract. The article presents assumptions, characteristics and conclusions of functional tests of a pilot implementation of a power restoration system in one of the Distribution System Operators. The main objective of conducted and described tests wasContinue reading “The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid”

Effect of Harmonics on Power Transformers: A Practical Demonstration and Analysis

Published by Munther Naif Thiab1, nmunther2@gmail.com, Kaleid waleed abid2, kaleidwaleedabid@gmail.com, Muhideen Abbas Hasan3, muhyabass@gmail.com,1, College of Engineering, University of Anbar, Iraq.2, Renewable Energy Research Center / University of Anbar. Iraq.3, Al-Dour Technical Institute, Northern Technical University, Iraq. Abstract: Voltage and current harmonics arise in the presence of nonlinear loads in the major supply. Moreover, theContinue reading “Effect of Harmonics on Power Transformers: A Practical Demonstration and Analysis”