Published by Yuriy SAYENKO1, Ryszard PAWEŁEK2, Andrii MOLCHAN1, Ewa DYKA2, Pryazovskyi State Technical University (1)Lodz University of Technology, Institute of Electrical Power Engineering (2) Abstract. The article presents results of experimental studies of power quality indicators conducted at the wind farm with 52 DFIG wind turbines with a unit capacity of 3.8 MW by GeneralContinue reading “Power Quality Experimental Research at the Primorsky Wind Power Station”
Tag Archives: Total Harmonic Distortion (THD)
Methods for Determining Power Losses in Cable Lines with Non-Linear Load
Published by Łukasz TOPOLSKI, Jurij WARECKI, Zbigniew HANZELKA, AGH University of Science and Technology Abstract. Harmonic currents in power cables cause additional power losses associated with phenomena that increase the temperature of the cable insulation and make its service life shorter. For these reasons, it is important to choose methods for determining active power losses,Continue reading “Methods for Determining Power Losses in Cable Lines with Non-Linear Load”
Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP
Published by Zia Hameed1, Muhammad Rafay Khan Sial2, Adnan Yousaf3, Muhammad Usman Hashmi,Faculty of Engineering and Technology, Superior University, 17-km off Raiwind Road Lahore PakistanEmails: zia.hameed@superior.edu.pk, rafay.khan@superior.edu.pk, adnan.yousaf@superior.edu.pk Abstract—Power System Harmonics is a real point of concern for Electrical Engineers. In power systems, non-linear loads are permanently connected, unlike transients and other distortions are produced.Continue reading “Harmonics in Electrical Power Systems and how to remove them by using filters in ETAP”
An Update IEEEE Standard Complements
Published by Sivaraman P, SMIEEE, PEng (India), Senior Power Systems Engineer Chennai, Tamil Nadu, India We all know that Total Harmonic Distortion (THD) and Total Demand Distortion (TDD) are used to evaluate the presence of harmonics in the power system. The “IEEE Std 1547-2018 IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with AssociatedContinue reading “An Update IEEEE Standard Complements”
Computer Assisted Harmonics Analysis
Published by Prof. Silviu Darie, PhD (EE), Technical University Cluj Napoca, Romania, Honorary Member of the Romanian Technical Sciences Academy. Email: silviu.darie@enm.utcluj.ro. Abstract: Based on the author’s experience one describes in field tested methodologies which can be employed in solving the frequency-based power quality problems. A generic approach is presented and an experience-based assessment isContinue reading “Computer Assisted Harmonics Analysis”