Published by Samira SEGHIR, Tahar BOUTHIBA, Université des Sciences et de la Technologie d’Oran Mohamed BOUDIAF, USTO-MB, Faculté de Génie Electrique, Laboratoire LGEO, BP 1505 El M’Naouer, 31000 Oran, Alegria Abstract. A distance protection relay plays a major role in faults detection in the electric transmission line. The fault resistance has an effect on theContinue reading “Impedance Correction Method of Distance Relay on High Voltage Transmission Line”
Tag Archives: Fault Location
Impedance-Differential Relay as a Transmission Line Fault Locator
Published by Justyna HERLENDER, Jan IŻYKOWSKI, Eugeniusz ROSOŁOWSKI, Wroclaw University of Science and Technology, Department of Electrical Power Engineering Abstract. This paper deals with analysis of impedance-differential protection applied to locating faults on power transmission line. Based on the voltage and current measurements at both line ends, the differential impedance is calculated. It enables toContinue reading “Impedance-Differential Relay as a Transmission Line Fault Locator”
Intelligent Redundant Measuring Circuit with Primary Circuit Error Detection
Published by Bartosz DOMINIKOWSKI, Politechnika Łódzka, Instytut Systemów Inżynierii Elektrycznej. ORCID: 1. 0000-0002-4762-2005 Abstract. Differential amplifiers in measuring systems are often exposed to external factors, which may lead to disturbance of their proper operation. Due to the capabilities of microprocessor systems, the intelligent algorithms work well in systems for diagnosing circuit errors such as aContinue reading “Intelligent Redundant Measuring Circuit with Primary Circuit Error Detection”
Accurate Fault Detection and Location in Power Transmission Line Using Concurrent Neuro Fuzzy Technique
Published by Patrick S. Pouabe Eboule, & Ali N. Hasan, University of Johannesburg, South Africa Abstract. In this paper a new approach for the detecting and locating different kinds of faults on power transmission lines using the concurrent neurofuzzy technique (CNF) is introduced. This approach relies on the advantages of combining fuzzy logic (FL) andContinue reading “Accurate Fault Detection and Location in Power Transmission Line Using Concurrent Neuro Fuzzy Technique”
Data-Driven Fault Detection and Diagnosis for Centralised Chilled Water Air Conditioning System
Published by Noor Asyikin SULAIMAN1, Kai Wern CHUINK1, Muhammad Noorazlan Shah ZAINUDIN1, Azdiana Md YUSOP1, Siti Fatimah SULAIMAN1, Md Pauzi ABDULLAH2, Centre for Telecommunication Research & Innovation (CeTRI), Fakulti Kejuruteraan Elektronik dan Kejuruteraan Komputer (FKEKK), Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100, Durian Tunggal, Melaka, Malaysia (1), Centre of Electrical Energy Systems (CEES),Continue reading “Data-Driven Fault Detection and Diagnosis for Centralised Chilled Water Air Conditioning System”
Faults Detection in PMSM Drive using Artificial Neural Network
Published by Konrad URBAŃSKI, Dariusz MAJCHRZAK,Poznań University of Technology Abstract. In this paper, simulation research results of PMSM drive with open phase fault detection are presented. Proposed fault detection system is implemented using two artificial neural networks. One of them is neural model of healthy PMSM and another one generates diagnostic signals. When the faultContinue reading “Faults Detection in PMSM Drive using Artificial Neural Network”
Detection of Fault Events in Medium Voltage Grid Based on Analysis of Data from Fault Recorders
Published by Dariusz SAJEWICZ1, Augustyn WÓJCIK2, Piotr ZEGADLO3,Bialystok University of Technology (1), Warsaw University of Technology (2), Kozminski University (3)ORCID: 1.0000-0002-3488-5674; 2.0000-0003-0597-1634; 3.0000-0002-0219-297X Abstract. The aim of this paper is to demonstrate the effectiveness of newly developed fault detection methods based on a simple statistical approach encompassing linear discriminant analysis and signal processing. Fault predictionContinue reading “Detection of Fault Events in Medium Voltage Grid Based on Analysis of Data from Fault Recorders”
Faults Detection and Classification on Parallel Transmission Lines using Modified Clarke’s Transformation-ANN Approach
Published by Makmur SAINI1, A. M. Shiddiq YUNUS1, Ahmad Rizal SULTAN1, Muh Ruswandi DJALAL1, Mohd. Wasir bin MUSTAFA2, Rahimuddin RAHIMUDDIN3, Ikhlas KITTA3, State Polytechnic of Ujung Pandang (1), University Teknologi Malaysia (2), Hasanuddin University (3) Abstract. This paper introduces a comparative study for fault detection and classification on parallel transmission line using cascade forward andContinue reading “Faults Detection and Classification on Parallel Transmission Lines using Modified Clarke’s Transformation-ANN Approach”
The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid
Published by Michał KONARSKI, Paweł WĘGIEREK, Lublin University of Technology, Faculty of Electrical Engineering and Computer Science, Lublin, Poland Abstract. The article presents assumptions, characteristics and conclusions of functional tests of a pilot implementation of a power restoration system in one of the Distribution System Operators. The main objective of conducted and described tests wasContinue reading “The use of Power Restoration Systems for Automation of Medium Voltage Distribution Grid”
Earth Fault Protection Supported with Adaptive Admittance Criteria
Published by Józef LORENC, Krzysztof ŁOWCZOWSKI, Bogdan STASZAKPolitechnika Poznańska, Instytut Elektroenergetyki Abstract. In this paper possibilities for improvement of earth fault protection by adjustment of protective relay settings due to change of neutral point impedance in medium voltage networks are presented. Streszczenie. W artykule przedstawiono zagadnienia dotyczące możliwości poprawy skuteczności działania zabezpieczeń ziemnozwarciowych typu YY0Continue reading “Earth Fault Protection Supported with Adaptive Admittance Criteria”