Published by Bożena E. MATUSIAK, Jerzy S. ZIELIŃSKI, University of Lodz Abstract. The aim of the paper are selected problems resulting from Renewable Energy Sources (RES) intrusion into Smart Grids (SG) presentation. Upon considerations there are: wind turbines influence on power system operation, RES and microgrids operation with a Power System, new Energy Market forContinue reading “Renewable Energy Sources Intrusion into Smart Grids – Selected Problems”
Category Archives: Smart Grid
Smart Meter and Cost Experiment
Published by Mehmet Sait CENGİZ1University of Yüzüncü Yıl (1) Abstract. System that all stakeholders compound the activities (production, transmission, distribution, sale, consumption) to product and to consume quality, constant, reliable and economic electric energy is called Smart Grid (SG) in electric. SG, which its most important component smart meter (Smart Metering-SM), are advanced energy meteringContinue reading “Smart Meter and Cost Experiment”
A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications
Published by Yang HAN1, Lin XU2University of Electronic Science and Technology of China (1), Shanghai Jiao Tong University (2) Abstract. This paper presents the survey of the smart grid technologies, including the background, motivation and practical applications. The driving forces for the smart grid technologies are presented, including the blackout, global energy crisis and environmentalContinue reading “A Survey of the Smart Grid Technologies: Background, Motivation and Practical Applications”
What is a DSO?
Published by European Distribution System Operators (E.DSO), Why smart grids?Website: edsoforsmartgrids.eu Distribution system operators (DSOs) are the operating managers (and sometimes owners) of energy distribution networks, operating at low, medium and, in some member states, high voltage levels (LV, MV). Transmission grids transport large quantities of high (and extreme high) voltage (HV, EHV) electricity across vastContinue reading “What is a DSO?”
Cyber-Physical System Security of a Power Grid: State-of-the-Art
Published by Chih-Che Sun 1, Chen-Ching Liu 1,2 and Jing Xie 1,* 1 School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA 99164,USA; csun@eecs.wsu.edu (C.-C.S.); liu@eecs.wsu.edu (C.-C.L.)2 Visiting Professor, School of Mechanical and Materials Engineering, University College Dublin, Belfield,Dublin 4, Ireland*Correspondence: jxie@eecs.wsu.edu; Tel.: +1-509-339-4246Academic Editors: Alfredo Vaccaro and Jin (Wei) Kocsis AbstractContinue reading “Cyber-Physical System Security of a Power Grid: State-of-the-Art”
China Smart Grid Strategy
Published by China Electric Power Technology Holdings Limited (CEPT), July 2009