Part 3 Power Quality: Definition and Discussion

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 3 Power Quality: Definition and Discussion”

Part 2 Reliability: Definition and Discussion

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 2 Reliability: Definition and Discussion”

Part 1: Introduction and Discussion of the Measurement “Toolkit”

Published by John D. Kueck and Brendan J. Kirby, Oak Ridge National Laboratory Philip N. Overholt, U.S. Department of Energy Lawrence C. Markel, Sentech, Inc. Published in Measurement Practices for Reliability and Power Quality: A Toolkit of Reliability Measurement Practices, 2004 Prepared by Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6285 managed by UT-BATTELLE, LLCContinue reading “Part 1: Introduction and Discussion of the Measurement “Toolkit””

Advances in Software for PQ Monitoring Systems

Published by Brian W Todd Vice President, Dranetz Technology, General Manager, Electrotek Concepts. Presented by Terry Chandler General Manager Asia, Director of Engineering, Power Quality Thailand LTD/Power Quality Inc., USA. Presented in 18th Annual PQSynergy™ International Conference and Exhibition 2018, Bangkok, Thailand. Website: pqsynergy.com

EMI Measurements: Methodology and Techniques

Published by Vladimir Kraz, OnFILTER, Inc. 3601-B Soquel, CA 95073 USA, Tel. +1-831-824-4052, Email: vkraz@onfilter.com Abstract This paper describes some aspects of methodology, instrumentation and techniques of measuring high-frequency electrical noise (EMI) in electronic manufacturing environment. High frequency measurements are quite different from typical ESD-related measurements which this paper explores. Introduction High-frequency noise (often, albeitContinue reading “EMI Measurements: Methodology and Techniques”

Power Quality (PQ) Standards IEEE-519™ -2014 Applicable for Industrial and Commercial Supply System

Published by Tushar Mogre, C.E.O. and Managing Director, TAS PowerTek Ltd. Presented in 18th Annual PQSynergy™ International Conference and Exhibition 2018, Bangkok, Thailand. Website: pqsynergy.com

Survey on Assessment of Power Quality Cost in Shanghai China

Published by Qing Zhong1, Wei Huang2, Shun Tao3, and Xiangning Xiao4 Abstract Power quality (PQ) issues cause a lot economic loss. It is very helpful for the governmental decisions of the PQ policies and supervisions to know the PQ loss from macroscopical aspects. This paper presents the procedure and some interesting findings of the surveyContinue reading “Survey on Assessment of Power Quality Cost in Shanghai China”

DC Current Sensors for Revenue-Grade Metering

Published by J&D is a world leader for high technology, high-performance current sensor that perfectly meet the needs of the metering sector. Email support@hqsensing.com Published in SMART ENERGY INTERNATIONAL ISSUE – 5 | 2018 A recent report by the US Electric Power Research Institute (EPRI) predicts that by 2020, the DC distribution market will accountContinue reading “DC Current Sensors for Revenue-Grade Metering”